background image

 

 

 

             Page 8 

7.1 Auto re-lock ON 

 
With Auto re-lock ON selected,  
the momentary connection of  
CL to + acts as the unlock signal.  
Closing the gate so the strike  
aligns with the lock and the  
magnet activates the internal  
switch, acts as the lock signal.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

7.2 Auto re-lock OFF 

 
With Auto re-lock OFF selected,  
the momentary connection of  
CL to + acts as both the lock  
and unlock signals for the GL10.  

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

YES 

NO 

YES 

NO 

YES 

NO 

YES 

NO 

GATE CLOSES 

HAS THE  

GATE OPENED? 

UNLOCK SIGNAL 

HAS THE BOLT PIN 

RETRACTED AFTER  

3 ATTEMPTS? 

GL10 IN STANDBY 

 

GATE IS

 

UNLOCKED  

 

GL10 IN STANDBY 

 

GATE IS LOCKED  

 

HAS THE BOLT PIN 

EXTENDED AFTER  

3 ATTEMPTS? 

HAS A LOCK  

SIGNAL BEEN SENT 

YES 

YES 

NO 

NO 

YES 

NO 

YES 

NO 

YES 

NO 

GATE CLOSES 

INTERNAL  

ALARM SOUNDS 

HAS THE BOLT PIN 

EXTENDED AFTER  

3 ATTEMPTS? 

IS THE  

GATE OPEN? 

HAS THE GATE 

OPENED WITHIN  

1 MINUTE? 

UNLOCK SIGNAL 

HAS THE BOLT PIN 

RETRACTED AFTER 

3 ATTEMPTS? 

GL10 IN STANDBY 

 

GATE IS UNLOCKED  

 

GL10 IN STANDBY 

 

GATE IS LOCKED  

 

IS THE TIMED  

RE-LOCK ON? 

INTERNAL  

ALARM SOUNDS 

INTERNAL  

ALARM SOUNDS 

INTERNAL  

ALARM SOUNDS 

Summary of Contents for GL10

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Electronic Gate Lock GL10 ...

Page 2: ...kes position o Drill the strikes mounting holes o Secure the strike in position o Wire the lock o Cover the lock WIRING OPERATING CONFIGURATION o Fail State o Auto re lock o Timed re lock o Diagnostic mode OPERATION o Auto re lock ON o Auto re lock OFF o General o Alarms SPECIFICATIONS DIMENSIONS o Lock o Strike MAINTENANCE WARRANTY UPGRADE 2 2 2 2 3 4 4 4 4 4 5 5 5 5 6 6 7 7 7 7 7 8 8 9 9 10 10 1...

Page 3: ...two keys Lock Strike Also included in the box are 4 x AA batteries Because of the various fitting locations of the GL10 no mounting bolts are supplied The mounting holes in the lock and strike are 8 5mm slotted holes so accept M8 size bolts 3 PRE INSTALLATION ASSESMENT 3 1 Mechanical Before the lock can be installed consider its location and orientation The GL10 can be mounted horizontally or down...

Page 4: ...stems to provide full monitoring Once the number of wires and their destination is determined it needs to be decided how the wires will enter the lock They can either come in through a 20mm weather proof wiring gland at the rear of the lock not supplied or through a hole under the locks base which will ensure the wires can be hidden Finally the correct wire gauge needs to be chosen to ensure a min...

Page 5: ...Drill the lock mounting holes Use a M8 drill bit to drill the three mounting holes in the fence post Check on the preferred wiring method and if running the wires through the base is desired also mark and drill the wire hole now See section 5 Wiring 4 3 Secure the lock in position Push the bolts through the fence post and position the lock over the protruding bolt ends Place nuts on the three bolt...

Page 6: ...s Place nuts on the three bolts and tighten them to secure the strike to the gate 4 7 Wire the lock Using a screwdriver and following the connection guide on the printed circuit board connect the required wires to the lock Detailed wiring information can be found in section 5 Wiring 4 8 Cover the lock Position the cover over the lock and push it down and forward Use the keyed cam lock in the back ...

Page 7: ...O Door Position Switch Normally open contact of the gate position monitor C Common contact of the gate position monitor There are two options available when running wires into the GL10 they can be brought in through a 20mm wiring gland not supplied in the rear of the cover or run discreetly through the hole in the locks base Running wires out of the lock via the hole in base ensures a more weather...

Page 8: ...e the gates position and automatically lock when it is closed is paramount to increasing security as it eliminates the need for the user to do so If Auto re lock is not selected the GL10 operates on a toggle method In this configuration an activation of the control signal will cause the GL10 to unlock and a second activation will cause it to lock assuming the strike is in place 6 3 Timed re lock S...

Page 9: ...NO GATE CLOSES HAS THE GATE OPENED UNLOCK SIGNAL HAS THE BOLT PIN RETRACTED AFTER 3 ATTEMPTS GL10 IN STANDBY GATE IS UNLOCKED GL10 IN STANDBY GATE IS LOCKED HAS THE BOLT PIN EXTENDED AFTER 3 ATTEMPTS HAS A LOCK SIGNAL BEEN SENT YES YES NO NO YES NO YES NO YES NO GATE CLOSES INTERNAL ALARM SOUNDS HAS THE BOLT PIN EXTENDED AFTER 3 ATTEMPTS IS THE GATE OPEN HAS THE GATE OPENED WITHIN 1 MINUTE UNLOCK ...

Page 10: ...uired If the batteries are not replaced once they have become depleted the GL10 will automatically revert to the Fail Maintained state i e in the event of a power failure the lock will stay in the position it was in before the power was removed The three monitors can be used to provide door and bolt position information regardless of the locks configuration Manual operation of the GL10 is availabl...

Page 11: ...s free to operate as normal 8 SPECIFICATIONS Bolt Pin Stainless Steel ø18mm 35mm stroke Lock Die Cast Aluminium 152mm x 88mm x 78mm Strike Die Cast Aluminium 75mm x 75mm x 70mm Holding Force 3000Kg 30000N Power Supply 12 24VDC 15 Durability 1 000 000 Operations Current Usage Holding 12V 15mA Operation 12V 300mA Stall 12V 2A 24V 15mA 24V 200mA 24V 1A Batteries 4 x AA 1 5VDC Alkaline Monitor Switche...

Page 12: ...nty against faulty or malfunctioning parts components or product At the manufacturer s discretion either a replacement lock or affected part will be supplied to remedy the fault Mistreatment or ill use of the lock may void the warranty dormakaba will not be liable for any direct indirect incidental or consequential loss or damage in any way related to this product 12 UPGRADE dormakaba reserves the...

Reviews: