5. Setting the zero position for the ITS 96
1
Open the single-action sliding panel/double-action sliding panel. Loosen the screw from the clamping piece (3 mm sock-
et wrench). The ITS 96 can now be adjusted ±2 mm in the zero position. Press the ITS in the direction of the offset side
and fix the screw afterwards.
For more adjustments of the closer, please follow the instructions in the installation manual.
1
2
3
4
3 mm
±2 mm
1
The opening limiters of door closers must not be used as door stops. Use a doorstop.
HSW EASY SAFE
27