3
HSW EASY SAFE
11
3.3
Glueing the door rails to the laminated safety glass panel (optional)
The clamping of the upper door rail is especially important due to the supporting function. If vibrations are expected on the
object the glass panels in the upper door rail area should be glued in addition to the clamping.
The chambers in the intermediate layer and the boreholes in the door rail have been pre-manufactured.
They are to the right and left on the face side on the inner side of the panel.
Install the door rail according to the general instructions (see chapter 3.2).
Inject the glue through the filling hole. As soon as the glue exits the outlet duct, the glue chamber is completely filled.
Remove the excess glue. The glue needs 10 minutes to harden. The panel can then be installed.
The glue is completely hardened after 24 hours and the normal operation of the system is possible.
Filling hole
Outlet duct for the
fill inspection
Glue chamber