Aligning the panels:
Align the single-action end panel F1 to the wall with a gap of 5 mm. Close all panels (bringing them to the front).
Now align the remaining panels (F2-F4) according to the already aligned single-action end panel (F1) with a gap
of 5 mm each.
F1 = Single-action
end panel
1
2
2
2
1
5
5
5
5
5
14
3.12 Aligning the panels in the stacking area
Slide the attached panel into the stacking area and align the panel laterally to the first panel. Carefully move the panel. The
rollers are not fixed at this point so that they will assume the correct distance in the stacking area. If necessary, loosen the
nut (c). Align the panel in the stacking area. Retighten the nut (c) once the alignment has been completed.
c
1
2
3
3
Lateral alignment
in the stacking area
F2 = Sliding wall
F3 = Double-action
sliding panel
with ITS 96
F4 = Fixed panel
3.13 Aligning the panels in the front area