dormakaba MUTO Premium XL150/80/120 / MUTO Comfort L80
Fixed Panel Installation Instructions
MUTO Premium/Comfort Fixed Panel
05-2018
936020
7
Track
2.3
Secure sidelite section profile to track and mounting surface
NOTE:
OVERHEAD REINFORCEMENT:
The overhead reinforcement must be a minimum of ¼”
[6] x 3” [76] steel angle, 16 gauge metal stud, or two
pieces of 1 1/2” [38] thick wood blocking (double
stacked), secured to studs or joists on a maximum 16”
[406] centers for the length of the track. The overhead
reinforcement may be flush on the overhead surface or
on the interior of this surface.
Track mounting screws must fully penetrate the steel
angle, metal stud, or at a minimum of 2” [51] into wood
blocking, utilizing the predrilled holes in the MUTO
track.
Consult with a structural engineer to determine if
reinforcement is adequate for your specific application
or to meet specific codes in your location.
2.3.1 Align sidelite profile screw slot with track profile
holes.
NOTE: Holes will be predrilled every 7-7/8” [200].
2.3.2 Secure with provided fasteners.
2.3.3 Ensure track is properly level and secure it to the
header mounting surface per the appropriate
measurements on the following page.
NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT
PAGE FOR REFERENCE.
2.3.4 Use appropriate fasteners according to the
following recommendations.
Fig. 2 MUTO ceiling mount track
Track
Sidelite
section
profile