dormakaba MUTO Electro Magnetic Lock
Installation Instructions
MUTO Premium
10-2018
936033
6
Mag lock
Fig. 4
2.4.1 Ensure mag lock and armature are
properly aligned.
2.3 Secure terminal block to door frame
Legend
Closing edge
of door
Armature
Mag lock
Mag
lock
5/8”
[15.4]
23/32”
[18.4]
2.4 Secure mag lock to wall/door frame structure
Fig. 5
2.3.1 Secure terminal mounting plate
to a concealed location in close
vacinity to mag lock.
(preferably
in jamb or above ceiling)
•
Use pre-attached fasteners (x4).
2.3.2 Secure terminal board to
mountg plate.
•
Use included M3x6mm PH
Phillips screws (x4).
Terminal
mounting
plate
Terminal
mounting
plate
fasteners
Terminal
board
M3x6mm
PH screws
Inside
door
jamb
MUTO SYSTEM HIDDEN FOR EASIER VIEWING
Side elevation
view of mag lock
Side panel
2.4.2 Remove side panel
from mag lock.
2.4.3 Secure mag lock onto wall/
door frame structure through
any of the holes in the mag
lock, as required per your
application.
•
Use appropriate fasteners
(not included).
MUTO
track
(Blocking by
others)
(Blocking by
others)
2”
[50]
1-3/16”
[30]
1/8”
[2.7]
Mag
lock
MUTO Track
(Blocking by others)
CL
(Blocking
by
others)
Armature
1-1/2”