background image

dormakaba MUTO Electro Magnetic Lock
Installation Instructions

MUTO Premium

10-2018

936033

8

Wiring

4.1  Wiring diagram

MEM Lock Wirng to PCB

Wire color

MEM Power Input, 12VDC

Black (-)

Connects to Power Input

Red (+)

EW Sensor Output

(EW = Early Warning)

Brown (C)

Connects to DSS if used

White (NC)

Grey (NO)

PCB Connection

Terminal Designation

Power Input

-

+12 VDC, 1A maximum

+

Exit Input

EXIT

Connects to customer dry trigger

DSS Sensor Input

DSS

Use jumper or Early Warning Sensor brown and white wires

MEM Lock Power Output

L-    (BLK)

Connect to Mag Lock

L+   (RED)

Alarm Relay Output 

30 VDC, 2A max.

120 VAC, 1A max.

NO

Use to trigger auxiliary LED, siren, alarm panel, etc.

NC

C

Alarm Relay Timer Input

TIMER

0 to 30 sec. delay timer (EW)

Contact closes to activate Alarm Relay Output

Use to trigger alarm panel or other.

NO
NC

C
EXIT

DSS

-+

L+

TIME

R

L-

RED

BLK

-+

Early Warning

Sensor

MEM4400 

mag lock

BLK

RED

30 Vdc 

0.2A max

Delay time increase on 

CW rotation 0 - 30 s

(optional Early Warning Timer)

Circuit board

C

NO

NC

12 - 24 Vdc

12Vdc, 0.28A

24 Vdc 0.14A

Customer 

Lock release

(Dry trigger)

MAG 

Lock

By customer

Relay1

Relay2

Alarm 

relay

(Input power)

C

NO

NC

Alarm panel 

contact

4  Wiring the circuit board

Summary of Contents for MUTO Elock MEM4400

Page 1: ...Muto Electro Magnetic Lock Elock MEM4400 Installation instructions Wiring manual 936033 10 2018 EN ...

Page 2: ... Safety instructions 3 1 1 5 Symbols used Safety Installation 3 1 1 6 Maintenance care repair 3 1 1 7 Disposal 3 1 2 Specifications technical data 4 1 3 Dimensions 4 2 Installation instructions 4 2 1 Overall 4 2 2 Secure armature bracket to rollers to glass or wood doors 5 2 3 Secure terminal block to door frame 6 2 4 Secure mag lock to wall door frame structure 6 3 Change handing of mag lock 7 3 ...

Page 3: ...stalling the glass avoid over tightening screws 1 1 4 Safety instructions Installation requires two people Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware Due to crushing hazards and possible injury caused by breakage of glass during mounting corresponding protective clothing especially gloves and protective goggles is required Work on electrica...

Page 4: ...Ceiling mount Door leaf weight lbs kg 330lbs 150 264lbs 120 Including weight of auxiliary hardware 1 1 MEM4400 mag lock 1 2 Circuit board 1 3 Armature 1 4 Armature bracket Fig 1 NOT TO SCALE 1 2 Specifications technical data 1 3 Dimensions Fig 2 1 2 1 1 1 4 1 3 2 48 2 11 16 68 3 1 2 88 For all MUTO XL150 less DM only applications For MUTO XL120 SC only applications For MUTO XL150 80 DM only applic...

Page 5: ... bracket to leading roller carrier Use included fasteners 2 2 Secure armature bracket to rollers to glass or wood doors Fig 3 Legend Closing edge of door Armature Armature bracket Leading roller carrier NOTE Ensure armature and bracket align with mag lock once installed Use any of the 3 screw slots in bracket to mount accordingly Armature bracket screw slots Glass cut out pre fab Mag lock Wood Doo...

Page 6: ...g Use pre attached fasteners x4 2 3 2 Secure terminal board to mountg plate Use included M3x6mm PH Phillips screws x4 Terminal mounting plate Terminal mounting plate fasteners Terminal board M3x6mm PH screws Inside door jamb MUTO SYSTEM HIDDEN FOR EASIER VIEWING Side elevation view of mag lock Side panel 2 4 2 Remove side panel from mag lock 2 4 3 Secure mag lock onto wall door frame structure thr...

Page 7: ...ctro Magnetic Lock Installation Instructions MUTO Premium 10 2018 936033 7 Mag lock Fig 6 3 1 Change handing 3 1 1 Rotate armature bracket in correct direction depending upon your application 3 Change handing of mag lock ...

Page 8: ... wires MEM Lock Power Output L BLK Connect to Mag Lock L RED Alarm Relay Output 30 VDC 2A max 120 VAC 1A max NO Use to trigger auxiliary LED siren alarm panel etc NC C Alarm Relay Timer Input TIMER 0 to 30 sec delay timer EW Contact closes to activate Alarm Relay Output Use to trigger alarm panel or other NO NC C EXIT DSS L TIMER L RED BLK Early Warning Sensor MEM4400 mag lock BLK RED 30 Vdc 0 2A ...

Page 9: ...www dormakaba com dormakaba USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...

Reviews: