Page 10
If the Failure to lock / unlock alarm has been sounded it is important that the cause of the obstruction is investigated
immediately. As the alarm sounds to indicate the bolt pin has not completed its correct action, it is possible that the
door is unsecured so the security of the building is at risk. Any obstruction that is identified needs to be cleared so
the lock is free to operate as normal.
8. SPECIFICATIONS
Bolt Pin
Stainless Steel, ø18mm, 35mm stroke
Lock
Die Cast Aluminium, 152mm x 88mm x 78mm
Strike
Die Cast Aluminium, 75mm x 75mm x 70mm
Holding Force
3000Kg (30000N)
Power Supply
12
– 24VDC ±15%
Durability
1,000,000 Operations
Current Usage
Holding
12V < 15mA
Operation
12V < 300mA
Stall
12V < 2A
24V < 15mA
24V < 200mA
24V < 1A
Batteries
4 x AA 1.5VDC Alkaline
Monitor Switches
Bolt position
– 60VDC, 0.2A
Door position
– 100VDC, 0.5A
9. DIMENSIONS
The dimensions shown are approximate and are subject to change without prior notice.
9.1 Lock