dormakaba USA Inc.  Remote Disable HW/SW Setup  7044.0822  Rev A 08/22  |  

 

4.

 

In the PC Link window, select Program from the left-hand column.  

5.

 

Verify that the correct COM port is selected. You can use the drop-down menu to 
switch ports. 

6.

 

Use the drop-down menu to select the Master user ID and enter the 
corresponding combination in the space provided. 
 
 
 
 
 

7.

 

From the list of system settings, ensure that Input Signal is checked off.  You can 
also check off any other setting you want to update/program, or check Select All 
to update/program all system settings. 

8.

 

Connect the Keypad to the PC by doing the following: 

a.

 

Plug the 700 Series USB Dongle into the USB Port of the PC. 

b.

 

Plug the USB-connector end of the cable into the dongle. 

c.

 

Plug the mini-USB end of the cable into the mini-USB port on the Keypad. 

9.

 

On the Keypad, enter a valid User ID and the corresponding combination (the 
same ID and combination used in step 6). 

10.

 

Using the arrow buttons on the Keypad, navigate through the Main Menu and 
select PC Link.  The LED on the Keypad will illuminate red, and “Connect 
Software” will appear on the keypad’s display screen. 

11.

 

In the software client PC Link window, click the Send icon located at the top-
right of the screen.   

 

A progress bar will appear onscreen.  As the Keypad is programmed, “PC Link active” 
will appear on the display screen and the LED will illuminate green. 

12.

 

When the programming is complete, “PC Link closed” will appear on the Keypad’s 
display screen, then the system will restart. 

Summary of Contents for Remote Disable

Page 1: ...able of Contents Introduction 2 About Remote Disable 2 Remote Disable LA GARD Software Setup 3 Remote Disable Keypad Setup 5 Display Keypad Setup 5 Non Display Keypad Setup 6 Alarm Box Input Signal Overview 6 Connecting the Input Signal 6 Mount the Alarm Box 6 Connect the Alarm Box 6 Alarm Box Connection Diagram 7 ...

Page 2: ...ime Delay Override Time Delay for all locks in the system is cancelled and any lock may be opened immediately by a user If one or more locks were in either the Delay Period or the Confirmation Window Time Delay is canceled and the lock can be opened immediately by a user with open privilege providing the correct credentials Dual User Override Dual User requirements are ignored allowing a single us...

Page 3: ...se your Systems list will appear blank If this is the case create a new System by clicking the Create icon 4 If creating a new System enter a System name in the space provided and configure all other fields settings based on your preferences For more information about LA GARD software and 700 series system settings please refer to the System User Guide Document 7040 1121 and the help menu included...

Page 4: ... the USB Port of the PC b Plug the USB connector end of the cable into the dongle c Plug the mini USB end of the cable into the mini USB port on the Keypad 9 On the Keypad enter a valid User ID and the corresponding combination the same ID and combination used in step 6 10 Using the arrow buttons on the Keypad navigate through the Main Menu and select PC Link The LED on the Keypad will illuminate ...

Page 5: ...splay Keypad Setup Follow these steps to configure the Input Signal on a Display Keypad 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select System 3 Select Input Signal from the sub menu 4 Scroll through the list of options and select Disable Open to set the Input Signal to Remote Disable mode 5 Success Mode updated will appear on screen and the Keypad will be...

Page 6: ... Input Signal This section outlines how to connect the Input Signal from your alarm control system to your 700 series Lock and Keypad using the Alarm Box to make use of the Remote Disable function Mount the Alarm Box Mount the Alarm Box to the interior safe wall via the holes and screws provided Connect the Alarm Box For multi lock configurations the silent alarm works only with the primary lock t...

Page 7: ...Document 7040 0320 for further instructions on how to change silent alarm and remote disable settings Alarm Box Connection Diagram Lock Connector Connect to BAT port on lock with 41040 2 cable 9V DC Connector Optional connection to 701107 AC Power Supply Kit Terminal Block Connection to alarm control panel 1 EXT Control Signal Reference Voltage or Ground 2 EX 5V DC Min to 12V DC Max Control Signal...

Reviews: