Optional: Connect AC Adapter to 9V DC connector. 

6.

 

Reconnect the safe lock to the system. 

7.

 

The default setting within the lock for silent alarms is set to OFF.  
 

Consult the System User Guide (Document #7040.0320) for further instructions on 
how to change silent alarm and remote disable settings. 

Alarm Box Connection Diagram  

 

 

            Lock Connector: Connect to BAT port on lock with 41040-2 cable.  

            9V DC Connector: Optional connection to 701107 AC Power Supply Kit.  

Terminal Block: Connection to alarm/control panel.  

1.

 

EXT- (Control Signal Reference Voltage or Ground) 

2.

 

EX+ (+5V DC Min. to +12V DC Max. Control Signal) 

3.

 

NO (Normally Open) 

4.

 

COM (Common) 

5.

 

NC (Normally Closed) 
 

 

 

 

9V 

DC 

Summary of Contents for Remote Disable

Page 1: ...able of Contents Introduction 2 About Remote Disable 2 Remote Disable LA GARD Software Setup 3 Remote Disable Keypad Setup 5 Display Keypad Setup 5 Non Display Keypad Setup 6 Alarm Box Input Signal Overview 6 Connecting the Input Signal 6 Mount the Alarm Box 6 Connect the Alarm Box 6 Alarm Box Connection Diagram 7 ...

Page 2: ...ime Delay Override Time Delay for all locks in the system is cancelled and any lock may be opened immediately by a user If one or more locks were in either the Delay Period or the Confirmation Window Time Delay is canceled and the lock can be opened immediately by a user with open privilege providing the correct credentials Dual User Override Dual User requirements are ignored allowing a single us...

Page 3: ...se your Systems list will appear blank If this is the case create a new System by clicking the Create icon 4 If creating a new System enter a System name in the space provided and configure all other fields settings based on your preferences For more information about LA GARD software and 700 series system settings please refer to the System User Guide Document 7040 1121 and the help menu included...

Page 4: ... the USB Port of the PC b Plug the USB connector end of the cable into the dongle c Plug the mini USB end of the cable into the mini USB port on the Keypad 9 On the Keypad enter a valid User ID and the corresponding combination the same ID and combination used in step 6 10 Using the arrow buttons on the Keypad navigate through the Main Menu and select PC Link The LED on the Keypad will illuminate ...

Page 5: ...splay Keypad Setup Follow these steps to configure the Input Signal on a Display Keypad 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select System 3 Select Input Signal from the sub menu 4 Scroll through the list of options and select Disable Open to set the Input Signal to Remote Disable mode 5 Success Mode updated will appear on screen and the Keypad will be...

Page 6: ... Input Signal This section outlines how to connect the Input Signal from your alarm control system to your 700 series Lock and Keypad using the Alarm Box to make use of the Remote Disable function Mount the Alarm Box Mount the Alarm Box to the interior safe wall via the holes and screws provided Connect the Alarm Box For multi lock configurations the silent alarm works only with the primary lock t...

Page 7: ...Document 7040 0320 for further instructions on how to change silent alarm and remote disable settings Alarm Box Connection Diagram Lock Connector Connect to BAT port on lock with 41040 2 cable 9V DC Connector Optional connection to 701107 AC Power Supply Kit Terminal Block Connection to alarm control panel 1 EXT Control Signal Reference Voltage or Ground 2 EX 5V DC Min to 12V DC Max Control Signal...

Reviews: