dormakaba Deutschland GmbH
DORMA Platz 1
58256 Ennepetal
Germany
T: +49 2333 793-0
F: +49 2333 793-4950
www.dormakaba.com
7 Status display
The door unit’s status display is indicated via the
illuminated ring on the emergency button. The LED
segments light up or blink in color depending on the
door status. In the event of an alarm, an signal sounds
as well.
WARNING
The service technician must be called
immediately in the event of a permanent
alarm or an unidentifiable display on the
illuminated ring.
Table of displays on the emergency button’s
illuminated ring
LED display
Door status
Recommended procedure
1. LED display in normal operation
The electric
door locking device is
activated.
–
A B C
The electric door locking
device is
A. briefly unlocked
B. unlocked long-term* or
C. permanently unlocked
–
2. LED display in case of alarm
“Door open” alarm
(one yellow LED per locking
device, here: 4 connected
locks)
Turn off the alarm signal (see Ch. 4.6)
Emergency button pressed
Turn off the alarm signal (see Ch. 4.6)
Alarm system triggered
After resetting the fire detector or smoke
switch, this alarm trigger is automatically
reset.
or
Tamper alarm
red-yellow = locked door
green-yellow = unlocked door
Check all the connected devices’ housings
for correct screw connection and seal them
correctly
if necessary. Turn off the alarm
signal (see Ch. 4.6). If the alarm continues,
call the service technician.
3. LED display in case of malfunction or maintenance
(no display)
Power supply is missing
or emergency button is
defective
Turn on the power.
If the LED display does not change, call the
service technician.
or
Maintenance required
• red-yellow = locked door
• green-yellow = unlocked
door
Inform the facility operator and/or call the
service technician.
*Long-term unlocking from Standard license
Tr
anslation o
f
the original documen
t, subjec
t
to change
witho
ut no
tic