dormakaba Deutschland GmbH
DORMA Platz 1
58256 Ennepetal Germany T: +49 2333 793-0 F: +49 2333 793-4950
www.dormakaba.com
Tr
anslation o
f
the original manual, subjec
t
to change
without no
tic
e
10 Maintenance
Perform the following maintenance steps
at least once a month
to ensure safe use of
the SVA/SVI lock:
1.
Check and operate all parts of the door lock.
Ensure that they are fully operational.
2.
Ensure all the parts provided have been mounted
and that no subsequent modifications have been
made or additional locking devices added.
3.
Make sure that the locking points are not blocked.
4.
Use a force gauge to measure and record the
actuating forces required to release the escape
door lock. The actuating forces may be max. 70
N for escape doors according to EN 179 and max.
80 N for escape doors according to EN 1125.
The actuating forces must not have changed
significantly compared to the measurement after
the initial installation.
5.
Clean the masking plate.
6.
Note the date of maintenance, the corrective
actions taken and the name of the person
performing the work.
TIPS AND RECOMMENDATIONS
The SVI solid door locks have a
permanent dry lubrication with
bonded coating.
• If necessary, supplementary lubrication
with Teflon spray (acetone-free) is
permitted.
11 Disassembly and disposal
Disassembly is carried out in reverse order of the
mounting instructions.
The product must not be disposed of in
domestic waste.
Dispose of the product in an environmentally
friendly manner at the arranged acceptance
and collection points.
Refer to the statutory regulations for your country.