3.2 Technical information
All SVI locks
Temperature range
-25°C to +70°C
Relative humidity:
up to 95 % at 55°C;
no condensation
DIN direction:
can be used left/right
Installation position:
vertical
Tubular
frame locks
Solid door
locks
Backset:
35, 40 or
45 mm
65, 80 or
100 mm
Rear backset:
15 mm
33 mm
Nut to inner square:
9 mm
9 mm
Forend
24 mm wide
20 mm or
24 mm wide
SVI 5000
Forend
310 mm high,
angular/
square
235 mm
high, round
SVI 4000
Forend
310 mm high,
angular/
square
235 mm
high, round
Contact load capacity: 100 mA at max. 30 V DC
Bolt contact’s contact
load capacity:
0.5A at max. 30 V DC *
SVI 2000 and SVI 2000F
Forend:
380 mm
high,
angular/
square
235 mm
high, round
Supply voltage:
24 V DC stabilized
(+/- 15 %)
Max. power
consumption:
0.5 A
Quiescent current
consumption:
0.08 A
Bolt contact’s contact
load capacity:
0.5A at max. 30V DC
“Locked” signal:
output switches to GND,
30 mA at max. 30 V DC
*only for special items
3.3 Variants
Versions of the SVI locks are available for various
applications:
• The
SVI 5000
is a mechanical lock. When the door is
closed, the lock locks automatically.
• The
SVI 4000
is an electrically monitored
lock. When the door is closed, the lock locks
automatically.
• The
SVI 2000
is a motorized lock whose function
can be controlled electronically. When the door is
closed, the lock locks automatically. It is operated
separately (Stand Alone) or on an external control
unit via a DCW® bus or a CAN bus. The SVI 2000
can be switched to "permanently open". Operation
on an electric door operator with integrated control
unit is also possible, e.g. with the ED 100/ED 250.
The SVI 2000 may only be used in fire and smoke
protection doors in combination with the external
Power Reserve module "SVP-PR DCW®" (item no:
70922601)!
• The
SVI 2000F
is a motorized lock with the same
functions as the SVI 2000, which is also approved
for use in fire and smoke protection doors. The
SVI 2000F contains an integrated Power Reserve
module. The SVI 2000F cannot be switched to
"permanently open" because this function is not
permitted for use on fire and smoke protection
doors.
5
SVI Lock
2019-12
dormakaba Mounting instructions
Product description
WN 059741 45532