background image

SVP/SVZ door locks

Mounting instructions

WN 059744 45532/14767 
2020-03

EN

Contents

About this document 

1

2 Safety 

2

Product description  

3

4 Mounting 

8

Parameterization (SVP 2000/2000F only) 

15

Integrated Power Reserve module test 
(SVP 2000F) 

18

Pin assignment 

18

Complete mounting  

19

Error messages 

20

10 Maintenance 

20

11 

Disassembly and disposal 

20

About this document

1.1  Contents and purpose

SVP/SVZ door locks are available in various designs 
for tubular frame doors and for solid doors. This 
manual describes mounting in tubular frame and solid 
doors.

1.2  Target group 

SVP/SVZ door locks must only be mounted by 
technically qualified personnel.

1.3  Other applicable documents

•  Manual for the connection cable SVP-A 1100/2100 

(not necessary for SVP 5000)

•  Mounting instructions for the components used, e.g. 

the door handle

1.4  Abbreviations

SVP

Emergency lock with self locking 
action

SVZ

Access control lock with 
self locking action, without 
emergency escape action

2000, 2000F, 
4000, 5000, 
6000

All versions of a door lock; the 
exact lock type is marked with 3 
digits instead of zeros.

TMS Soft®

Software for the dormakaba 
door management system (TMS)

DCW® bus

DCW® is the short form for 
"DORMA Connect & Work".  
A dormakaba-owned fieldbus 
system for the connection of up 
to 4 identical components to a 
DCW® central unit.

CAN bus

Serial fieldbus system according 
to ISO 11898-3, for connecting 
several components to one cable 
harness

RR

Tubular frame locks

VB

Solid door locks

1.5  Symbols used

1.5.1  Hazard categories

WARNING

This signal word indicates a possible 
hazardous situation which may result in 
death or serious injury if not averted.

ATTENTION

This signal word indicates a situation of 
potential risk, which could lead to damage 
to property or the environment if not 
averted.

TIPS AND RECOMMENDATIONS

This signal word indicates useful information 
for efficient and trouble-free operation.

1.5.2  More symbols

1.

2.

Sequence of action steps

1

2

Item numbers used in image 

caption

Summary of Contents for SVP

Page 1: ...g action SVZ Access control lock with self locking action without emergency escape action 2000 2000F 4000 5000 6000 All versions of a door lock the exact lock type is marked with 3 digits instead of zeros TMS Soft Software for the dormakaba door management system TMS DCW bus DCW is the short form for DORMA Connect Work A dormakaba owned fieldbus system for the connection of up to 4 identical compo...

Page 2: ...ollowed The following SVP door locks are suitable for use on fire and smoke protection doors SVP 5000 SVP 4000 SVP 6000 SVZ 6000 SVP 2000F The SVP 2000 may only be used in fire and smoke protection doors in combination with the external Power Reserve module SVP PR DCW item no 70922601 If an SVP 2000 or SVP 2000F is operated in Stand Alone mode in a fire and smoke protection door the use of a smoke...

Page 3: ...P2000F 4 Door closer or door operator 5 Door contact TC optional 6 Access control components 3 3 Technical information All SVP SVZ door locks Temperature range 25 C to 70 C Relative humidity up to 95 at 55 C no condensation Protection category IP 54 DIN direction SVP 6xxx only SVP 6xxx only can be used left right DIN left DIN right Installation position vertical Tubular frame locks Solid door lock...

Page 4: ...must not be used along escape routes because it does not have an emergency escape function The SVP 2000 is a motorized lock whose function can be controlled electronically When the door is closed the door lock locks automatically It is operated separately stand alone without feedback contacts or on an external control unit via a DCW bus or a CAN bus Operation on an electric door operator with inte...

Page 5: ...R module SVP PR DCW item no 70922601 operation mode Stand Alone 3 5 2 Solid door locks dormakaba Deutschland GmbH Postfach 4009 58247 Ennepetal 0432 CPR 00026 19 15 SVP 4000 VB SVP 5000 VB EN 12209 2003 AC 2005 3 X 9 1 0 G 7 B B 2 0 DOP_0160 0432 CPR 00026 08 15 SVP 2000 VB EN 14846 2008 3 S 5 E 0 L 7 1 1 3 DOP_0161 0432 CPR 00026 08 15 SVP 2000F VB EN 14846 2008 3 S 5 E 0 L 7 1 1 3 DOP_0161 0432 ...

Page 6: ...luded Fig 3 1 2 3 Parts included 1 Door lock 2 Lipped striking plate 3 Screws 3 6 2 Lock dimensions Fig 4 5 14 5 Lock dimensions Material 1 4301 6 SVP SVZ door locks 2020 03 WN 059744 45532 dormakaba Mounting instructions Product description ...

Page 7: ...C B D 2 8 A B C D 2 5 40 24 28 50 50 232 104 30 30 50 28 104 101 50 76 70 170 76 20 3 A B C D 16 5 33 55 60 65 Ø6 90 20 209 235 30 41 5 20 10 7 22 12 13 Ø7 Ø8 Ø7 21 5 38 35 63 79 5 17 5 165 Ø10 9 5 12 5 5 8 100 0 max 45 max 45 80 PZ 80 5 RZ 72 PZ 74 RZ PZ RZ 12 5 12 5 Lock dimensions 3 7 3 Door versions Fig 7 A B Rebated doors Fig 8 D C Flush doors Material 1 4016 7 SVP SVZ door locks 2020 03 WN 0...

Page 8: ...pens in the escape direction If the door opens in the opposite direction to the escape direction a building authority permit must be obtained There are recesses and pre drilled holes in the door leaf see chapter 4 4 There are recesses and pre drilled holes in the door frame see chapter 4 4 For all locks except SVP 5000 The door leaf is equipped with the connection cable SVP A 1100 2100 If the door...

Page 9: ... Fig 10 1 ST 3 9x19 A2 70 EN ISO 7050 2 depending on fitting 3 45 at backset 35 50 at backset 40 55 at backset 45 Cut outs and pre drilled holes in door leaf Fig 11 Cut outs and pre drilled holes in door frame 9 SVP SVZ door locks 2020 03 WN 059744 45532 dormakaba Mounting instructions Mounting ...

Page 10: ...98 21 5 73 13 Ø 10 Ø 22 38 55 20 18 20 18 124 85 ø 22 ø10 ø7 8 100 0 55 60 65 R6 13 9 ø7 13 2 R6 8 26 20 5 Fig 13 24 18 124 26 2 5 119 24 X 28 28 56 15 3 24 232 89 28 13 85 13 209 235 1 185 80 72 PZ 74 RZ 98 21 5 73 13 Ø 10 Ø 22 38 55 60 65 55 X ø7 ø 22 ø 10 ø7 8 100 0 7 104 56 14 28 Cut outs and pre drilled holes in the door leaf and door frame with a lipped striking plate 10 SVP SVZ door locks 2...

Page 11: ...frame lock 1 Connect the cable Fig 15 TIPS AND RECOMMENDATIONS If a lock is being replaced a cable with a severed bridge can still be used Fig 15 SVP 2000 SVP 2000F SVP 4000 SVP 6000 SVZ 6000 SVP 5000 Connect cable 2 Insert the door lock into the door leaf recess Fig 16 Fig 16 Insert door lock 3 Screw the door lock tight Fig 17 Fig 17 Screw door lock tight 11 SVP SVZ door locks 2020 03 WN 059744 4...

Page 12: ...5000 SVP 6000 Mount door handle and locking cylinder 5 Adjust the striking plate Fig 19 Fig 19 X 28 X X 28 X X 45 Dimensions of the adjustments 6 Mount the striking plate Fig 20 Fig 20 Mount striking plate 12 SVP SVZ door locks 2020 03 WN 059744 45532 dormakaba Mounting instructions Mounting ...

Page 13: ...ck into the door leaf cut out Fig 23 Fig 23 C o m p r e s s e d a i r a i r c o m p r i m é D r u c k l u f t Insert door lock 4 Screw the door lock tight Fig 24 Fig 24 Screw door lock tight 5 Attention Risk of property damage due to the use of an incorrect cylinder screw with the locks SVP 2000 and SVP 2000F Mount the door handle and locking cylinder Fig 25 For SVP 2000 2000F locks use only the s...

Page 14: ...g plate Fig 26 Fig 26 X 28 X X 28 X X 45 Dimensions of the adjustments 7 Mount the striking plate Fig 27 Fig 27 or Mount striking plate 14 SVP SVZ door locks 2020 03 WN 059744 45532 dormakaba Mounting instructions Mounting ...

Page 15: ...es 1 to 4 If a door lock with address 1 is already connected to the door a different address must be set on the second SVP door lock see chapters 5 6 1 and 5 6 2 5 2 3 End resistor In the CAN bus operation mode the terminating resistor must be switched on for the door lock with the greatest distance to the bus center point 5 3 Default settings Parameter Default setting Operation mode DCW bus Bus a...

Page 16: ...re for at least 10 s Symbol Operating method To jump from one selection to the next Turn the door key briefly in the locking cylinder in the unlocking direction until it stops To jump from setting to setting within a selection Briefly press down the door handle until it stops Fig 30 Operation mode DCW address CAN address Terminating resistor only with SafeRoute components with the Multi door licen...

Page 17: ... Turn the key briefly in the unlocking direction until it stops The LED flashes red or green The signal repeats itself after a 2 s pause 9 Press the door handle down repeatedly until the desired terminating resistor function is reached LED flashes green or red 10 Turn the key in the unlocking direction until it stops and hold it there for 10 s The LED flashes green for 2 s and then lights up const...

Page 18: ... 2000 F SVP A 1100 2100 cable colors Operation mode DCW CAN Stand Alone PIN 1 bk GND GND GND PIN 2 rd Unlock 1 leaf pull input to GND via a switch PIN 3 wh 24V DC 24V DC 24V DC PIN 4 PIN 5 bn Unlock 2 leaf pull input to GND via a switch PIN 6 vio Locked output switches to GND max 30 mA Locked output switches to GND max 30 mA Locked output switches to GND max 30 mA PIN 7 rd bu PIN 8 bu External doo...

Page 19: ...king devices added 3 Make sure that the locking points are not blocked 4 Use a force gauge to measure and record the actuating forces required to release the escape door lock The actuating forces may be max 70 N for escape doors according to EN 179 and max 80 N for escape doors according to EN 1125 5 This manual must be handed over to the facility operator and regular maintenance and recording dut...

Page 20: ...lockcase 1 Check and operate all parts of the door lock Ensure that they are fully operational 2 Ensure all the parts provided have been mounted and that no subsequent modifications have been made or additional locking devices added 3 Make sure that the locking points are not blocked 4 Use a force gauge to measure and record the actuating forces required to release the escape door lock The actuati...

Reviews: