3 Product description
3.1 Basic functions
SVP/SVZ door locks lock swing doors automatically
and immediately after each closing by automatically
pushing the bolt into the striking plate (insurance-
compliant lock). At the same time, the cross latch
blocks so that a two-point locking system is created.
This offers additional security against manipulation
or breaking of the door lock. In case of emergency,
the SVP door locks (except SVZ) can be unlocked and
opened in the escape direction at any time using the
door handle. These features ensure that SVP door
locks (except SVZ) comply with EN 179 for emergency
exit devices and EN 1125 for panic exit devices. The
SVP/SVZ door locks 4000, 6000 and 2000/2000F
can query the status of the control latch, dead bolt,
door handle and locking cylinder.
3.2 Installation situation
Fig. 2
SVP/SVZ
1
3
4
5
2
6
Additional components (not for SVP 5000)
1
Cable transfer CT, cable spiral CS and if
necessary detachable cable transfer DT
2
Connecting cable SVP-A 1100/2100
3
Control unit, e.g. SVP-S 3x/4x (optional for
SVP 2000/SVP2000F)
4
Door closer or door operator
5
Door contact TC (optional)
6
Access control components
3.3 Technical information
All SVP/SVZ door locks
Temperature range
-25°C to +70°C
Relative humidity:
up to 95 % at 55 °C;
no condensation
Protection category:
IP 54
DIN direction:
SVP 6xxx only:
SVP 6xxx only:
can be used left/right
DIN left
DIN right
Installation position:
vertical
Tubular
frame locks
Solid door
locks
Backset:
35, 40 or
45 mm
55, 60, 65, 80
or 100 mm
Rear backset:
15 mm
33 mm
Forend:
24 mm wide,
270 mm high,
angular/
square
20 mm or
24 mm wide
235 mm high,
round
Distance between
door handle and
locking cylinder
(center-center-
distance):
92 mm
for profile
cylinder
94 mm
for round
cylinder
72 mm
profile
cylinder
74 mm round
cylinder
Follower to inner
square:
9 mm
Dead bolt throw:
20 mm
SVP 5000
Supply voltage:
none (mechanical only)
Power consumption:
none (mechanical only)
SVP 4000, SVP 6000 and SVZ 6000
Supply voltage:
12 – 24 V DC stabilized
(+/- 10 %)
Power consumption:
0.15 A (max. 0.3 A)
Contact load capacity: 100 mA at max. 30 V DC
SVP 2000 and SVP 2000F
Supply voltage:
24 V DC stabilized
(+/- 15 %)
Power consumption:
0.05 A (max. 0.3 A)
Bus operation:
DCW® bus or
CAN bus (ISO 11898-3)
3
SVP/SVZ door locks
2020-03
WN 059744 45532
dormakaba Mounting instructions
Product description