4 Mounting
4.1 Safety during mounting
WARNING
Danger to life from crowding in front of a
jammed door.
If the door leaf is deformed by more than
5 mm, the door may not always open
reliably!
• SVP door locks should only be installed in
doors with a maximum deformation of
5 mm!
• In case of more severe deformation, verify
that the door opens reliably with the
fitting!
TIPS AND RECOMMENDATIONS
• The mounting is shown on a DIN-left door.
For a DIN-right door, the procedure must
be mirror-inverted.
• The mounting is shown with a long plate.
For other door fittings, other mounting
points may have to be used.
TIPS AND RECOMMENDATIONS
Mounting on fire and smoke protection
doors is only permitted if the usability
certificates for these doors provide for
the mounting, and if the requirements are
followed.
4.2 Requirements for mounting
• The door corresponds to the specifications in Fig. 9
and is deformed by a maximum of 5 mm.
• For mounting along escape routes:
The door opens in the escape direction. If the door
opens in the opposite direction to the escape
direction, a building authority permit must be
obtained.
• There are recesses and pre-drilled holes in the door
leaf (see chapter 4.4).
• There are recesses and pre-drilled holes in the door
frame (see chapter 4.4).
• For all locks except SVP 5000:
The door leaf is equipped with the connection cable
SVP-A 1100/2100.
• If the door leaf is equipped with the SVP-A 1000
connection cable, then the "SVP-A Adapter
(A1000)" must be used (item no: 70932991).
Fig. 9
Requirements for the door
4.3 Tools and auxiliary materials
The following must also be available on site:
• a locking cylinder – a profile cylinder or a round
cylinder depending on the perforation in the lock
case and in the door leaf
• for the inner side of the door: one door handle
(according to EN 179) or one panic bar (according to
EN 1125)
• for the outer side of the door: one door knob
• for SVP/SVZ 6000: a 2nd door handle (for
SVP 6000: with splitted spindle) and an access
control component which controls the magnet with
a voltage between 12-24 V DC.
8
SVP/SVZ door locks
2020-03
WN 059744 45532
dormakaba Mounting instructions