Operating conditions
Cold water temperature
41 – 77 °F
Hot water temperature
131 – 149 °F
Recommended hot water
temperature
140 °F
Thermal disinfection (5:00 mins.) ≤ 158 °F
Permissible flow pressure
15 – 73 psi
Recommended flow pressure
45 psi
The customer has to provide a pressure
reducer in the main line downstream of the
water meter to comply with the noise levels
according to the noise class at a resting
pressure above 500 kPa / 73 psi / 5 bar.
If combined with continuous-flow heaters,
the minimum flow volume of the safety shut-
off has to be considered.
Observe the manufacturer‘s instructions for
the continuous-flow heater.
DE
Betriebsbedingungen
Kaltwassertemperatur
5 – 25 °C
Warmwassertemperatur
55 – 65 °C
Empfohlene Warmwassertemperatur 60 °C
Thermische Desinfektion (5:00 Min.) ≤ 70 °C
Zulässiger Fließdruck
1 – 5 bar
Empfohlener Fließdruck
3 bar
Ein Druckminderer ist bauseits in der
Hauptleitung hinter dem Wasserzähler
einzubauen, um bei einem Ruhedruck über
500 kPa / 73 psi / 5 bar die Geräuschwerte
der Geräuschklasse einzuhalten.
Bei Kombination mit Durchlauferhitzern
ist die Mindestdurchflussmenge der
Sicherheitsabschaltung zu berücksichtigen.
Beachten Sie die Herstellerhinweise des
Durchlauferhitzers.