Dorner Mfg. Corp.
14
851-738 Rev. A
Brushless DC Motor Control
Operation
4.
Press up or down
to change the
speed (e.g., 1000 r/min)
. Pressing
and holding the key for 3 seconds or more will increase
or decrease the value successively.
Figure 27
Figure 27
5.
After the speed has been changed, press SET
28, item 1)
to confirm the new setting. The display will
, after which
the acceleration time
will be
displayed
Figure 28
Figure 28
6.
Press up or down
to change the
.
Pressing and holding the key for 3 seconds or more will
increase or decrease the value successively
Figure 29
Figure 29
7.
After the acceleration time has been changed, press SET
to confirm the new setting. The
display will blink and show “dEc1”
,
after which the deceleration time
will be displayed.
Figure 30
Figure 30
8.
Press up or down
to change the
deceleration time (e.g., 5.0)
.
Pressing and holding the key for 3 seconds or more will
increase or decrease the value successively.
Figure 31
Figure 31
9.
After the deceleration time has been changed, press SET
to confirm the new setting. The
display will blink.
Figure 32
Figure 32
10. Press MODE to switch to the monitor mode.
NOTE
Minimum Speed = 100 rpm
Maximum Speed = 3000 rpm
1
2
1 second
later
1
2
3
1
2
1 second
later
1
2
3
1
2
1