6.3 Product connection
IN
Eco
MCC3
low pressure color change valves max. 20 bar
only used on circuit A (base
)
You must use 1/8 "gas female threaded connection
(1)
1/8” gas female connections
(2)
, are normally plugged, and they are used only in case of paint
recirculation.
EcoValve7 20 color low pressure change valves max. 20 bar
only used on circuit B (hardener)
You must use threaded 1/8 "gas female connection
( 1-2 )
EcoMCC200 high pressure color change valves
(max .160 bar with Coriolis) (max. 200 bar with Gear)
Used on circuit A (base
)
and
on circuit B (hardener).
You must use threaded 1/8 "gas female connection
W A R N I N G
You must use suitable fittings and pipes to the operating pressure and to the paints
Follow the instructions by the fittings’ manufacturer for tightening torques
You must install a shutoff valve on all product lines, in order to safely perform maintenance
operations.