8.5.3.2
Valves manual control
Requirement for manual control valves:
-
control voltage must be switched on
-
manual mode must be selected
To toggle the valve status, open or closed, you must tap the valve symbol
Valve closed. Valve opens with a touch
Valve opened. Valve closes with touch
The number of color and hardener valve to command, is selected by means of dropdown menus
near the valve symbol.
Interlocks do not allow to open more valves at the same time in the same channel,
however valves must be opened with caution and the system finally purged.
BZL1, BFDS1 for gun 1, and BZL2, BFDS2 for gun 2 are analog valves.
Tap on the valve symbol to open a popup window, in Manual mode tap on the symbol
to
switch on the valve.
Adjust the analog set value of the valve: the set value can be written directly, or incremented /
decremented of 0.1 bar at a time, with the + / - keys.