8.5.4
Spray data
Figure 40 Spray data page
While the system is spraying the window displays:
-
the current flow in channel A (color channel) in ml/min
-
the current flow in channel B ( channel) in ml/min
-
the current flow in channel C (channel )
-
the current flow of mixed material in ml/min
-
the dispensed quantity of A, B and mixed A+B and A+B+C in liter.
-
The quantities are reset each time there is an alarm which locks the spray.
-
The mixing ratios deviation: difference between the requested ratio and the actual ratio in
percentage.
-
For the equipped systems with Coriolis flowmeter the temperature and the density of fluids in
A, B and C channels are also available.
-
Current consumption during the spraying cycle in progress. The consumption totalization can
be activated locally pressing the button START, or in external recipe mode with the command
mStartCons in the command interface; the totalization continues until the signal is on and is
reset on a new rising edge of the signal.
-
For the equipped systems with Coriolis flowmeter the temperature and the density of fluids in
A, B and C channels are also available.
On the right the mixed material flow in the gun hoses is shown.