DELAY FINAL STOP
ALARM [s]
To access this parameter, the option AUTOMATIC MACHINE must be set to
No, it means the system is not used to supply an automatic machine.
While spraying, if the flow of A or B falls consistently below the minimum set
limit MINIMUM FLOW A or B or C, after the time DELAY ALARM NO FLOW,
an acoustic alarm is raised. The operator has still the time here specified to
solve the problem and let the medium flow before the alarm stops the system.
Then a reset command on the panel is necessary. Default value 4 [s]
Figure 46 Parameters page 3
PIPE SIZE
In order to save component C, in the first loading operation, the valve C is open to mix A+B with C,
after the quantity specified in milliliter in the parameter “Mixed A+B pipe volume” has flowed.
HOSES SIZE
Here is set the internal hose diameter, default value 6 [mm], and the hoses length, default value 7
[m].
Accordingly the hose volume is calculated in ml.