FLOW CONTROL
Pressure or Closed loop.
Pressure standard value: a consistent value of pressure, assigned by the
operator, is applied to the flow regulator.
On system with one spray gun, equipped with a flow modulating valve, can
be activated, when available, a closed loop flow control: assigned a flow set
point value, while spraying, the control pressure of the regulator is
automatically adjusted, to control the flow.
REGISTER
CONSUMPTION TIME
name-h:m
At the time here indicated the daily quantity consumed of solvents, colors and
components B and C for each recipe, is saved in a CSV format file on the
flash memory of the controller, accessible by FTP connection. The saved file
name is composed of the pair of characters written in the name box, followed
by the date of the day when the writing took place. Leave empty the name
field if you do not want to write the file, with subsequent reset of consumption
totalizations.
YRF1-2 closed at
load ending
For system equipped with valves which control the gun’s needle, at the end
of the load YRF can be closed and the needle is automatically opened. Here
is defined the quantity, at the end of the loading cycle, which has to pass
through the needle. Set this quantity to zero to keep YRF always open while
loading.