Figure 48 Parameters page 5
TEMPERATURE
ALARM
THRESHOLDS [C°],
DELAY ALARM
TEMPERATURE [s]
Only for system equipped with Coriolis flowmeter
While spraying the temperature of color and component B and C are
controlled. If the values of the temperature are consistently out of the intervals
here specified, after the time specified in DELAY ALARM TEMPERATURE,
an alarm is raised. If the temperature threshold values are set to 0 [C°] this
alarm is excluded.
DENSITY ALARM
THRESHOLDS [kg/l],
DELAY ALARM
DENSITY [s]
Only for system equipped with Coriolis flowmeter
While spraying the density of color and component B and C are controlled. If
the values of the density is consistently out of the intervals here specified,
after the time specified in DELAY ALARM DENSITY, an alarm is raised. If the
temperature threshold values are set to 0 [C°] this alarm is excluded.