8.12 Remote magnetic switch panel
The system can be equipped with a remote magnetic switch panel, separated from an Ex
hazardous area by a glass wall. The operator, staying in the paint booth, can activate the main
commands with a magnet.
8.12.1 Available commands
The available commands are:
PURGE
to start a purging cycle. The magnet must be placed in front of the sensor and hold in
place for a short time. While the purging cycle is running the white lamp is flashing.
Activate again the switch while the cycle is running to stop it. Once the system is purged
the white lamp is steady on.
LOAD
to start a loading cycle. The magnet must be placed in front of the sensor and hold in
place for a short time. While loading cycle is running the green lamp is flashing. Activate
again the switch while the cycle is running to stop it. Once the system is loaded, the
green lamp is steady on.
RESET
ALARM
to silence the siren and reset an alarm. When there is an alarm and the siren is on, the
red lamp is flashing. Place the magnet in front of the sensor a first time to silence the
siren. The red lamp is steady on. Alarm messages and warning can be red on the panel.
Place the magnet in front of the sensor a second time to reset the alarm.