7.3
A
larms management on PLC for consumable components
A T T E N T I O N
The control system provides a warning message "MAXIMUM NUMBER OF PULSES
ACHIEVED, PROVIDE MAINTENANCE" for consumable components.
EcoMCC3 20
low pressure
color change valves
EcoValve7 20
low pressure
color change valves
EcoMCC 200
high pressure
color change valves
Coriolis Flow Control
Gear Flow Control
The number of cycles life of such components, must be set the during installation, depending on
the type of material, its degree of abrasiveness and on working conditions.
For the correct functioning of the apparatus, these parameters must be calibrated depending on
the specific application chosen.
The initial settings on
Eco
Dose
3K are absolutely indicative, and they do not determine any
definition of the guarantees.
Pre-set values are indicative and they refer to tests performed with Mesamol oil.