The 4300 series 2-Door interlock controller is an inexpensive alternative for two door mantraps. It features 
two powered relay outputs for direct connection to locks and traffic lights. It may be easily configured during 
installation for locked, unlocked or locked-unlocked operation by means of jumpers. It includes an override 
function to unlock one or both doors remotely, bypassing the interlock. 

 

 

 

Power Input – 12 or 24 VDC 

 

Lock Power Output 

Control Inputs 

 

Optional Non-powered Outputs 

Configuration Jumper Matrix 

 

Remote Lock Override 

Output Fuses 

 

Relay State Indicator LEDs 

 

FIG. 1   CONTROLLER DIAGRAM 

 

1.3 

Summary of Contents for 4300 Series

Page 1: ...n to locks and traffic lights It may be easily configured during installation for locked unlocked or locked unlocked operation by means of jumpers It includes an override function to unlock one or both doors remotely bypassing the interlock A Power Input 12 or 24 VDC E Lock Power Output B Control Inputs F Optional Non powered Outputs C Configuration Jumper Matrix G Remote Lock Override D Output Fu...

Page 2: ... supervised Fire Alarm Interface The supply will drop low voltage power to the locks when the fire alarm circuit goes active Refer to the Power Supply User s Manual included for more details The 4300 controller comes mounted on an aluminum plate with DIN rail clips The plate may be unclipped to make wire connections more convenient and then snapped into place when done Use a small screw driver to ...

Page 3: ... with a strike or they may be connected to the dry contact non fused outputs RLY 1 Door 1 AWG 22 gauge or larger is recommended for signaling and low power indicator circuits PANIC EGRESS OR REMOTE UNLOCK The 4300 controller includes a remote lock override function The Remote lock override terminals Fig 1G may be connected to a set of dry contacts On closure the associated door lock relay will ene...

Page 4: ...eyed and non keyed They may be connected to the Remote inputs to provide an interlock override for immediate egress regardless of door status 5200 Series 4 Amp Power Supply For double door or paired maglock installations the 4 Amp power supply is recommended 4202 4 Battery Backup 7 Amp hour battery backup for locks and controller fits in the enclosure and can provide up to 6 hours of continuous se...

Page 5: ...4300 MANUAL 1 2 Page 5 of 6 rev 12 9 2021 DORTRONICS SYSTEMS INC OPERATION INSTALLATION NOTES ...

Page 6: ...placed or repaired based upon incoming evaluation and inspection All other Dortronics components of the Electric Locking System shall be similarly warranted for a period of one year Expressed warranties are conditionally based on the requirement that the items covered within the guarantee are used and maintained in accordance with the manufacturer s recommendations A Return Authorization Number mu...