rev:12.07.17
WARNING!
While testing the installation follow the safety rules in order to avoid improper direction of airflow,
i.e. open chimney duct or other devices with open fire towards room.
3.2.
Connecting control panel
Air handling unit is equipped with weekly controller.
Control panel is delivered with 20 m connection cord ended with plug type RJ11.
Control panel should be placed on a wall, but you should previosuly plan how to lead cord from unit to panel.
WARNING!!! Cord cannot be less than 5m long.
3.3.
Starting the unit
1. Read the manual
2. See if there is no damage
3. Place unit in wanted place
4. Connect control panel
5. Connect connection cord to power grid 230 V
6. Turn on the unit using control panel ot turn on "TURBO" mode for 3 minutes
7. Check if there is air flow at the stub-pipes (WARNING! Do not put hands inside the stub-pipes
- may results in injuries!)
8. Turn off the unit using control panel
9. Unplug power cord from grid
10. Disconnect control panel from unit
11. Mount the unit in ventilation system
12. Lead control panel's cord from unit to destined mounting place
13. Mount control panel
14. Connect unit to control panel
15. Connect power cord to power grid
16. Turn on control panel and set weekly program
17. Control air intake efficiency in accordane with project
Once all above is performed, the unit can be used.
Optimal 400/600
EN