3. Flow efficiency characteristics OPTIMAL 600 bypass

Optimal 

600 BYPASS

3

v [m /h]

Optimal 400/600

EN

Summary of Contents for OPTIMAL 400 BYPASS

Page 1: ...rev 12 07 17 MAINTENANCE MANUAL WARRANTY CARD AIR HANDLING UNIT OPTIMAL Below documentation shall be kept by user In case of not following the conditions of this document the warranty expires EN ...

Page 2: ...5 Connecting to ventilation 2 6 Connecting to power grid 3 STARTING THE UNIT 3 1 General remarks 3 2 Connecting contol panel 3 3 Starting the unit 3 4 Usage and maintenance 3 5 Summer mode OPTIMAL 400 bypass 600 bypass 3 6 Working with carbon monoxide sensor option 4 EXPLOITATION RECOMMENDATION 5 ELECTRICAL CONNECTION AUTOMATION MODULE 5 1 Assembly and disassembly of automation module 5 2 Connecti...

Page 3: ...sulation class Internationl protection rating Weight roller bearing max 52dB A 1m I IP40 max 53dB A 1m 1400 rpm 1650 rpm up to 95 OPTIMAL 400 BYPASS OPTIMAL 600 BYPASS OPTIMALair handling unit is destined for air exchange in residential buildings The purpose of the unit is to bring fresh air from the outside and to siphon off used air from the rooms with simultaneous heat recovery 1 GENERAL INFORM...

Page 4: ...rev 12 07 17 2 Flow efficiency characteristics OPTIMAL 400 bypass Optimal 400 BYPASS 3 v m h Optimal 400 600 1 Nominal dimensions of OPTIMAL 583 570 375 175 838 725 198 178 478 625 EN ...

Page 5: ...rev 12 07 17 3 Flow efficiency characteristics OPTIMAL 600 bypass Optimal 600 BYPASS 3 v m h Optimal 400 600 EN ...

Page 6: ...referring to ventilation in residential and public utility buildings 2 The unit is not destined for drying the unseasoned houses 3 In case of damage to elements arising from not following the above instructions they will be not repaired under warranty 4 Due to design reasons there is a possibility of mixing the air inside the unit with amount not exceeding 2 Prior to connecting the unit check elem...

Page 7: ...siphoning out the condensate Exemplary way of conneting the pipe is shown below The pipe should have adequate diameter to the stub pipe 1 2 It shoud be bent into letter U and suffused with water until stabilizing its level Shipon should be palced around 150 mm from the unit and radius should not be less than R 30 mm Given measures should be taken as minimal Optimal 400 600 4 Proper positioning of ...

Page 8: ...in temparature below 12 C and above 32 C it is recommended to insulate ventilation ducts with mineral wool of min thickenss 30 mm Such operation will assure efficient work of the ventilation system 2 5 Connection to ventilation Optimal 400 600 6 Designation of the unit with stub pipe description Automation module From rooms To rooms From intake port To launcher Exttract fan Intake fan Supply volta...

Page 9: ...ected from the power outlet by pulling the plug out In case of damaging the wire replacement can only be performed by authorized person 1 Prior to starting the unit read the manual 2 Check if there is no objects present in the ducts which may damage the unit or endanger health 3 It is recommended to test the working mode of the unit prior to connecting it to ventilation 3 STARTING THE UNIT 3 1 Gen...

Page 10: ... Place unit in wanted place 4 Connect control panel 5 Connect connection cord to power grid 230 V 6 Turn on the unit using control panel ot turn on TURBO mode for 3 minutes 7 Check if there is air flow at the stub pipes WARNING Do not put hands inside the stub pipes may results in injuries 8 Turn off the unit using control panel 9 Unplug power cord from grid 10 Disconnect control panel from unit 1...

Page 11: ...om power grid 2 Disconnect control panel from the unit 3 Dismount the casing by unscrewing butterfly screws 4 Carefully take out used filters and replace with new ones 5 Mount back the casing and screw with butterfly screws 6 Connect power cord and control panel 7 Connect unit to power grid 8 Reset the timer WARNING Unit should not work without filters It is only recommended for testing but no lon...

Page 12: ...400 by pass 600 b pass ar equipped with automatic by pass The moment when by pass is opened hear exchange does not take place By pass is used for cooling ventilated rooms with the use of cool air for example from GWC Switch presented on the picture below in position By Pass Manual means opening the actuator It closes when outter temperature falls below 10 Switching to By Pass Auto means automated ...

Page 13: ...or tiled stove room with gas burners bathroom with warm water gas heaters boiler house garage or workshops Unit working with carbon monoxide sensor results in exhaust and intake fans to work on maximum speed Decrease of carbon monoxide in air allows unit to return to normal operation mode Detailed description of carbon monoxide sensor can be found in manual Optimal 400 600 A2 12V 12V GND Detektor ...

Page 14: ...in water Solid dirt can be cleaned with denaturated alcohol Prior to placing back dry well Control of condensate s stub pipe Stub pipe can become dirty overtime by fixed particles brought by air It is recommended to periodically check by flushing with water stub pipe patency Clean if needed ź ź 4 Exploitation Recommendation ź Unit is a part of a whole system the system supplies fresh air and launc...

Page 15: ... Unscew screws holding module inside the unit 6 pcs 5 Remove module from the casing 6 Disconnect fans temperature sensor and bypass Assembly is performed in reversed order Once performed start unit Connections in automation module are carried in accordance with scheme attached to this document WARNING Disassembled module can be connected by authorized person on prepared test stand only Module is e...

Page 16: ...ue Blue Blue Blue Blue Green Yellow Green Yellow Green Brown OPTIMAL mkII OPTIMAL 400 600 Brown Red 3 Yellow 2 2 2 2 2 2 3 3 3 3 2 2 2 2 2 2 3 3 3 4 4 4 6 5 5 5 7 D B B A C C B B A C C Yellow Yellow Yellow Yellow Yellow Yellow White White Blue Blue Blue Blue Red Red Red Red SWITCHED MODE POWER SUPPLY SKS 350 48 Red Red Brown Brown Black Black Intake fan Exhaust fan Anti frost sensor Bypass sensor ...

Page 17: ...URE SENSOR NTC 10K PROTECTION DEGREE IP30 DISPLAY LCD ASSEMBLY CONNECTION SCHEME rev 12 07 17 Optimal 400 600 CONTROLLER S DESCRIPTION RT TEMPERATURE without RT AIR FLOW ROOM TEMPERATURE DAY OF THE WEEK CLOCK INTAKE DEGREE DECREASING INTAKE INCREASING DEGREE INTAKE VIEW CLOCK SET UP TURN ON BOOST ON OFF POWER SUPPLY DC 12V 15V DIMENSIONS 86x86x13 mm CASING ABS FLAME RESITANT OPERATION RATING TEMPE...

Page 18: ...ode Press to set minutes Press or zmienić nastawę minut Again press to set hours Press or to set hours Press to set day of the week Using or choose accurate day of the week Mo Tu We Th Fr Sa Su is shown when intake is is above 60 maximum value is shown when inatke is between 30 60 maximum value is shown when intake is below 30 maximum value Press and hold for 3 seconds until number 1 and Mo Monday...

Page 19: ...uption Sound power level L wa dB A 52 53 3 m h W 140 200 Unit Internal leakage rate Filter change warning signal Website Annual electricity consumption 2 per 100 m Control factor CTRL The annual heating saved cold climate The annual heating saved average climate Internal leakage rate The annual heating saved warm climate Flow rate Pressure difference rate Specific power input SPI Product informati...

Page 20: ...wa tel 48 34 365 98 43 fax 48 34 360 97 00 e mail dospel dospel com www dospel com Dospel reserves the right to introduce any changes regarding its products resulting from ongoing technical development Dospel shall not be liable for printing errors ...