2. Operation 
 

For configuring the data logger, please install the Software DE-LOG-Graph on a PC. 

 

2.1 USB-Port 

When the Software Installation has been completed please connect the PC with data logger via USB-
cable. For detailed information please read the manual of the DE-LOG-Graph – Software. 
 
 

 
 

 

2.2 Panel and display 

Log100/110 has a large display, two LEDs and two buttons. 
 
 
 

 

 
 
 

LCD-display indicate humidity, temperature, 
external temperature(in case of an external 
sensor), Low bat-warning, Max-Min-Avg-
measurements, status information 
 
 
 
Start-Stop-button 

LED: green/red 
 
USB 

Mode-button 

 

 
 
 
 
 

2.3 Buttons-handling 

On the front panel there are two buttons. Both buttons can be de activated by using the Software DE-
LOG-Graph, to prevent unauthorized use. 

Start-Stop-button: 

 

Depending on the  setup configuration, you can start or Stop the data logger via the mentioned Start-
Stop-buttons. You have to press and hold the buttons 3 seconds. When it starts a short acoustic 
signal and the green LED- will flash and the display indication will switch from STOP to LOG. 

Mode-button: 

 

By pressing the Mode-button you will see on the bottom line the Average(AVG)-, Minimum(MIN)- and 
Maximum(MAX) temperature of the recorded measurements. If the data logger is not started it will 
display --- instead of AVG, MIN or MAX temperature. 

 

 

 

 

 

AVG: Average 

MIN: Minimum 

MAX: Maximum 

AUT: Auto-switch 

 

 

 

By using the AUTO-Mode(AUT) the display will switch automatically every two seconds. 

Summary of Contents for LOG100

Page 1: ...Log100_englisch_V010310_ohne_Software Data logger Log100 110 English Manual ...

Page 2: ... operating 1 3 Standard settings factory defaults 1 4 Marking 2 Operation 2 1 USB connection 2 2 Panel and display 2 3 Buttons handling 2 4 LCD display Segments 2 5 LED and Buzzer 2 6 USB port 2 7 Data logger rear side Battery case 2 8 Replacement battery ...

Page 3: ...of the data logger before first use By using the DE LOG Graph software the setting parameter can easily be changed 1 Description blank max 16 characters 2 LCD Snooze mode X 3 LCD Snooze after Sec 10 4 Mode button active X 5 Alarm settings for temperature X 30 0 C X 70 0 C X 40 0 C X 150 0 C Alarm settings humidity X 0 0 X 100 0 6 Alarm delay 0 cycle 7 Alarm cumulation off 8 Alarm indication LED an...

Page 4: ...el there are two buttons Both buttons can be de activated by using the Software DE LOG Graph to prevent unauthorized use Start Stop button Depending on the setup configuration you can start or Stop the data logger via the mentioned Start Stop buttons You have to press and hold the buttons 3 seconds When it starts a short acoustic signal and the green LED will flash and the display indication will ...

Page 5: ...ximum measurements will be displayed Unit Measurement 2 display the current measuring unit of measurement 2 MAXMINAVG display the average minimum or maximum measurements Status info display the operation mode LOG or STOP LOG indicates the recording mode and STOP indicates standby mode External probe EXT is displayed when an external sensor is connected In the lower display line the measurement 2 i...

Page 6: ...t forget to plug the rubber cap back into the port It prevents dirt and water from entering the data logger USB port with rubber cap 2 7 Rear side of the data logger battery case On the rear side of the data logger you will find the battery case and a printed sticker Marking Battery cover 2 8 Replacing battery To replace the battery please open the battery cover on the rear side Therefore you have...

Reviews: