5.9 Alerts
Beeper sounds once each 30 seconds
for 1 second, red LED blinks each
3 seconds – measured values exceeds
selected alarm settings(not with standard
settings). Via Software LogConnect
alarm levels can be set.
If an alarm level has been occurred a X will be displayed on the
display bottom. On the corresponding PDF-report the alarm status
will be indicated, too.
If the measurement channel is displayed where an alarm occurred
the X on the right bottom of the display is blinking.
The X disappears when the instrument has been restarted for
recording!
Red LED blinks once each 4 seconds.
Replace battery.
blinks twice or more each 4 sconds.
Hardware fault!
5.8.1 Set Date and Time after battery replacement via button
After battery replacement or power interrupt the instrument automa-
tically changes into the configuration mode to set date, time and
interval. If no button will be pressed for 20 seconds the unit pro-
ceeds with the last date and time in memory:
Press N=
No changing of
date and time, or
Press Y=Yes for
changing date
and time
Press Mode-button to increase
the value, press Start-button for
jumping to the next value
Press N=
No to abort
changings, or
Press Y=Yes
to confirm
changings
→
→
→
→
...
* LogConnect download link to access the software http://download.
dostmann-service.de , select Downloads/Software/5005-0200_
LOG200/Software/
6. Technische Daten
Temperature
Measuring range: -40..+70°C
Resolution: 0.1°C
Rel. Humidity only LOG210/LOG220
Measuring range: 0..100%rF
Resolution:
0.1%rF
Pressure only LOG220
Measuring range: 300-1100hPa
Resolution:
0.1 hPa
Memory:
LOG200:
150.000 measurements (Temp.+ motion)
LOG210:
Approx. 100.000 data set (Temp., Humidity,
dewpoint and motion)
LOG220:
Approx. 60.000 data set
(Temp., Humidity, pressure, dewpoint and
motion)
Interface:
USB (integr.)
Dimensions:
91.5 x 42 x 20 mm
Weight:
Approx. 83 g, Incl. Wall holder
Battery
:
1 x 3,6 Volt Lithium ½ AA