background image

- 1 -

R20160721

ZH2014-11003

Product

Bracket 2ea

User's Manual

 Technical  Specifications

Power

100–240Vac, 50/60Hz

Current

MAX 6 VA

Connection

Screw Bolt Connector(1.5mm

2

 Wire Use Possibility)

Output

Relay Output 1 Point (250Vac/16A)

Input

Temp. Sensor Input 1 Point

Dimensions

78(W)mm X 35(H)mm X 78(D)mm

Operation

Temperature: -10 ~ 50°C, Humidity: Below 90%RH

Storage

Temperature: -20 ~ 60°C, Humidity: Below 90%RH

Ordering guide

FX3S-00

Basic Model (220Vac)

FX3S-00-T

Basic Model (12Vdc)

FX3S-00-H

Basic Model (24/48Vdc)

※ Specifications are subject to change without prior notice.

Components

Accessories

User’s Manual

Ø5

35

SUS PIPE

SHRINK TUBE

LEAD WIRE

Ø6

100

SUS PIPE

SPRING PROTECT

LEAD WIRE

DPR-TH01-ET

 : NTC 5 KΩ at 25 °C / -50~105 °C / ±0.3 °C at 25 °C

DPR-TH02-P6D100L 

: NTC 10 KΩ at 25 °C / -50~150 °C / ±1.5 °C at 25 °C

Digital Temperature Control

User's Manual

FX3S

- Selection of Output(Heating/Cooling)
- Precise Temperature Control
- Sensor Calibration
- Sensor Error Detection
- Auto Save and Restoration of Parameter Values
- Minimum On/Off Duration Time Setup
- Minimum Duty Cycle Output Setup

DOTECH INC. 

   

6F, JOONGANG-ILBO B/D, 30, Dongsan-ro, Danwon-gu, Ansan-si, Gyeonggi-do, KOREA 

Cautions

1. This product may cause an electric shock in handling. Please do not attempt to open it with power turned on.

2. This product should be installed in a place fixed secured by a rack or panel.

3. This product can be used under the following environmental condition. 

 Indoor 

 Pollution Degree 2 

 At an altitude of 2000m or below

4. Power input must be within the designated ranges.

5.  To turn on or turn off power supply for this product, please the circuit breaker or switch of a standard product of IEC 60947-1 or IEC 60947-3 product 

and install it within a close distance allowing convenient operation by user.

6. Please be understood that if this product is dismantled or modified discretionary, after sales service will not be able to be provided.

7.  An output wire to be used for this product should be inflammable grade FV1 (V-1 grade or above), the thickness of the wire should be AWG No. 20 or 

above(0.50mm

2

).

8. In order to prevent it from an inductive noise, please maintain the high-voltage wire and power wire separated.

9. Please avoid installing the product in a place where a strong magnetism, noise, severe vibration and impact exist.

10. When extending the sensor wire, use a shield wire and do not extend it unnecessary long.

11. The sensor wire and signal wire should be away from the power and load wires using conduits separately installed.

12.  Please avoid using the product near a device generating strong high frequency noise (high-frequency welding machine, high-frequency sewing 

machine, high-frequency radiotelegraph, high capacity SCR controller)

13. Product’s damages other than those decribed in the guarantee conditions provided by the manufacturer shall not be respoinsible by us.

14.  If this unit is used to control machineries (Medical equipment, vehicle, train, airplane, combustion apparatus, entertainment, processing and 

transportation equipment, elevator and various safety device etc.) enabling to effect on human or property, it is required to install fail-safe device.

 The Aforementioned precautions must be observed, and if you fail to do so, it may cause a product’s breakdown.

 The specifications, dimensions, and etc. are subject to change for enhancement without a prior notice.