background image

- 2 -

R20160721

35

78

70

28

8

UNIT : mm

90

40

(Panel Cut-Out : 71mm X 29mm)

L2

L1

100-240Vac,

50/60Hz

1 2

4 5 6

8 9

NTC

COM

FX3S

c

16A, 250Vac

POWER

SUPPLY

NTC

OUT1

+ -

12Vdc

1 2

FX3S-00-T

POWER

SUPPLY

+ -

24Vdc

/ 48Vdc

1 2

FX3S-00-H

POWER

SUPPLY

FX3S

OUT1

Dimensions and Panel Cut-Out Form

Wiring

Constitution 

(Function of Display Lamp and Button)

No

Label

Description

1

POWER

100-240Vac, 50/60Hz

2

4

OUT1

(Relay output)

Relay output OUT1 when closed

5

Common signal

6

Relay output OUT1 when open

8

SENSOR

(NTC)

Common signal

9

Temperature sensor input

LED

OUT1

Turn on when output #1 is ON (Flickering at standby)

°C  /  °F

Celsius / Fahrenheit display units

ON at trip, Flickering at alarm

Parameter set up locked

BUTTON

PRG

Use at program setup

SEL

Execute selected menu or Input setup value

Move between menus & Increase setup value

Move between menus & Decrease setup value

PRG

 + 

If pushing for 10 sec. at the same time ,
setup value is initialized

Code

Menu

Description / Instructions

Response at 

Detection

Reset Type

DEF

Natural defrost

Present temperature and 

DEF

 message display by turns at natural defrost.

Immediate Stop

Code

Menu

Description / Instructions

Response at 

Detection

Reset Type

SYS

Internal 

Parameter Error

In Case of change of set value by an unknown case.

Immediate Stop

Automatic Reset

OPN

Sensor Open

In case of Input sensor open wire(Normal operation after sensor connecting)

Immediate Stop

Automatic Reset

SHT

Sensor Short

In case of Input sensor short circuit

Immediate Stop

Automatic Reset

LLL

Lower Input

Lower sensor input than measuring range

Immediate Stop

Automatic Reset

HHH

Higher Input

Higher sensor input than measuring range

Immediate Stop

Automatic Reset

 Trip / AlarmLARM MESSAGES

Display Message

 In case of error occurring, the following messages are flickering at every 0.5 sec. intervals.