background image

 

10 

 

 

Mounting S-Type Enclosure

 

Attaching Enclosure to Dotworkz Strong-Arm:

  Provided on S-Type equipment for Ring of Fire™  & COOLDOME models™

Locate & assemble four ¼”-20 x 5/8” hex bolts with lock washers provided in hardware pack of Strong-Arm.

Turn over S-Type housing to show threaded base inserts, pre-install four ¼” diameter bolts in Tilt head of Strong-Arm.  Note orientation of tilt locking 
screws toward rear of S-Type.  Firmly tighten all four bolts to secure tilt mount to S-Type housing.

Mounting to wall requires four user supplied fasteners.  Mark pilot holes for four (4) mount holes either by marking with base, or using template guide 
on back page of this manual.  Drill pilot holes and bolt arm to wall securely.  Four holes on S-Type arm will accommodate up to 5/16” diameter bolts.  
Always assure there is strong backing material & the proper strong & secure to anchoring into aggregate material of wall is made.

Wire feed can be directly into hollow of Arm, with room for wire management within Arm body. Hole on side of mount arm, and feeds on 

bottom of S-Type housing are clearance holes that will accept ½” NPT fittings or PG13 equivalent. A plug is provided with Arm hardware if this feed 
hole is not used.  Some customers will choose to provide & use liquid tight fittings & conduit to make the connection arm feed and S-Type enclosure. 

Always create a drip loop between all external conduit or cable connections between fittings and S-Type Housing.  All cable feeds must be 

sealed before S-Type housing is put into service to provide dry, electrically safe, and effective product performance.  

Wall Mounting

              

Always consult and follow all local and applicable electrical codes to install and service housing.  Always shut off power before 

installation and follow all applicable safety practices and guidelines.  Only qualified electrical technicians should prepare & service wiring.  Fully read & 
understand all installation guidelines before attempting to install wiring & housing.

Site wiring can be installed behind, or installed to side of base of the S-Type Strong-Arm.  Main body of this Arm has room for flush electric 

box, or cable feed thru wall to be mounted behind mounting base.  Prepare wiring before installation of this housing mount, allowing strong backing 
material to secure Strong-Arm mount.  Hole on side of mount arm and on bottom of S-Type housing are clearance holes that will accept ½” NPT 
fittings or PG13 equivalent.  

Wiring Notes:

Re-assemble Housing with Pan-Tilt onto Mount Arm by securing two side screws for pan adjustment.  Secure & tighten both screws evenly, also adjust 
& tighten tilt screws into desired final position.  Be sure all fasteners are evenly and securely tightened. After completing wiring, close access door to 
wire feed on mount, complete internal wire & cable installation, and close and seal housing top & wire feed seals.

Summary of Contents for COOLDOME S-Type Encolosure series

Page 1: ...Includes MVP COOLDOME models...

Page 2: ...r Installation 5 24V Input MVP Power 6 110 220 VAC High Voltage Input MVP Power 7 Camera Power Standard 12VDC Connector NON STANDARD 24V CONNECTIONS 8 Generic Camera Bracket Installation 9 Wall Mounti...

Page 3: ...ed to any of the following abuse improper use negligence accidents lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlin...

Page 4: ...thin an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of...

Page 5: ...to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camer...

Page 6: ...o conduit feed mouth 4 Push plug into conduit mouth with finger tips till it flush with outside of fitting 5 Repeat steps 1 4 for any other conduit feeds as needed 6 To assure an airtight seal caulk a...

Page 7: ...only 1 10 Power Supply S 250 indoor style in COOLDOME option only 1 Included in S Type Package Not Included in this Package Camera Installation Tools Wall Mounting Bolts Hardware Pole Mount Straps Str...

Page 8: ...6 Socket wrench or box open end wrench or adjustable wrench Wire stripping tool For Wall Mounting Drill and Bits for user supplied fasteners for wall mounting enclosure For Pole Mounting Strapping Ban...

Page 9: ...ll ST MVP is a Chassis similar to shown Locate Green Plug on Chassis Then Unplug from panel mount socket then push aside Connections are made fully inside of ST Then insert similar Plug on 24V Bypass...

Page 10: ...Electrical Working Temp 20 70C MTBF 353 6Khrs min MIL HDBK 217F 25C Power Available to Camera Accessories max MVP using 110 220 VAC input to S Type enclosure Using ONE Output Using BOTH Output Channel...

Page 11: ...osures come standard with a 12VDC Right Angle Barrel Plug 3 3mm x 5 5mm with a 1mm center pin for majority of the IP cameras on the market Camera Power Setup STANDARD 12VDC CONNECTOR Right Angle Stand...

Page 12: ...9...

Page 13: ...e enclosure Always create a drip loop between all external conduit or cable connections between fittings and S Type Housing All cable feeds must be sealed before S Type housing is put into service to...

Page 14: ...lways consult and follow all local and applicable electrical codes to install and service housing Always shut off power before installation and follow all applicable safety practices and guidelines On...

Page 15: ...ide screws removed in first step re assemble Tilt bracket to wall mount as shown Loosen then re tighten screws for Pan Tilt adjustment to arrange housing to desired viewing angle Securely tighten all...

Page 16: ...Safety Ground Front of Power Supply with terminal strip Rear of Power Supply with Input Voltage Selector Select Input Voltage before Hooking up Power Supply 110 VAC or 220 VAC Low Voltage 12 VDC Outp...

Page 17: ...ut Voltage 90 132VAC 176 264VAC Selected by Switch Frequency Range 47 63 HZ Input Current Full Load Typ 4A 115VAC 2A 230VAC Recommended Min Circuit Breaker for 110VAC In 10 A type C Int Electrical Wor...

Page 18: ...15...

Page 19: ...16 S Type Exploded Detail S Type Mounting Detail Strapping Slots wide cl Not to Scale 2 1 3 4 5 6 7 8 9 1 1 1 0 1 2...

Page 20: ...17 S Type Standard Arm Mounting Pattern Holes diameter clearance Not to Scale...

Page 21: ...18 S Type Strong Arm Mount Wall Mounting Pattern Not to Scale...