background image

 

14 

 

 

External Power Supply

The output of the S-250-12 external power  supply, can be adjusted up and down 10%.   It is recommended to keep 

the voltage at the S-Type adjusted to at least 11.5 vdc, but no more than 13.5 vdc.  By running the enclosure higher than 13.5 
vdc may cause premature fan failure.  

It is best to check and tune the voltage at the COOLDOME™  with a voltage meter at 

the time of installation, and use the adjustment screw, located on the S-250-12, to the right side of the terminal screws, to 
raise or lower the output voltage.

For all outdoor wiring, always use an outdoor rated wiring, or wiring in weather rated conduit, out from power supply, 

into the COOLDOME™ . Follow all local and applicable wiring and safety standards. 

Please keep D/C wire runs short, to reduce low voltage line drop

.  Also, the  suggested wiring gauge table is 

provided on previous page to further prevent low voltage line drop, and  to guide you in selecting the proper wire gauge for the 
dc run from the power supply to the ST-CD.  

 It is always advisable to use a  drip loop on all wiring going directly into the ST enclosure, to reduce the risk of water 

entering and damaging internal components.  All fittings and seals must be firmly tightened and sealed, before placing the ST-
CD in service.

Inside the ST-CD we have provided a convenient Screw cage clamp style terminal blocks to wire the 12 vdc positive 

(V+),  and the 12 vdc Negative (V-) terminal.  Please strip the insulation off the last 3/8

” of the wires and fasten wiring securely 

to terminal, using a small blade screwdriver to tighten the caging mechanism on the terminal blocks.  

Please be especially attentive to wire using the Proper Polarity, so as not to damage the internal components, or 

damage your camera within.

Power Supply Specifications

Input Voltage: 90-132VAC/ 176-264VAC Selected by Switch
Frequency Range: 47- 63 HZ
Input Current @ Full Load(Typ.):  4A @115VAC, 2A @230VAC
Recommended Min. Circuit Breaker for 110VAC In: 10 A (type C)
Int. Electrical. Working Temp*: -20 ~ +70C
Ext. Power Supply Output: 18A @ 12VDC up to 50C
Derate 0.5A/ deg. C over 50C

COOLDOME

™  Specifications

Current Draw by COOLDOME @ 12VDC:
Active Cooler OFF: 0.4A/ Active Cooler Peak On: 10.5A
Active Cooler On Typ.: 9.0A/ (Cam. Draw Not Incl.)
MTBF: 238.9Khrs min. MIL-HDBK-217F(25C)

COOLDOME

™  Input Power Configuration: ST-CD-12VDC

LOW VOLTAGE RUN:  Voltage Drop Table (shown on prior page)

Where we conservatively try to keep the voltage drop under  1.2 vdc over the low voltage direct current run.  These multipliers 

are approximate, and voltage drop (Vd) is maximum at full 12 amp load at 12 vdc.  This voltage drop is under fully loaded condition, when 
the cooling unit is engaged, and camera and all accessories are on.  Voltage drop will be much less,  if the current is not at full load.

Reusable Desiccant Canister

The reusable desiccant canister contains forty grams of silica gel.  This will prevent moisture 

buildup inside the COOLDOME™ .  Make sure to remove the canister from its foil envelope packaging 
before the COOLDOME™  is put to use.  

There is a small window on the canister (white circle).  Ensure that the crystals are blue.  

Occasionally, especially in humid environments, the canister may need to be serviced.  If so, the crystals in 
the window turns pink, indicating the silica gel is saturated with moisture and can be reactivated by being 
placed in an oven at 300 °F for three hours or until the crystals turn blue again.  The gel can be reactivated 
virtually an infinite number of times.

Warning!!!:

  COOLDOME Enclosure runs on 12 VDC only!  If high voltage is applied directly to COOLDOME™  

enclosure, you will damage housing, void warranty, and create electrocution hazard that can be harmful or fatal. 
Do not start wiring until you have fully read and understand these installation instructions.  

Summary of Contents for COOLDOME S-Type Encolosure series

Page 1: ...Includes MVP COOLDOME models...

Page 2: ...r Installation 5 24V Input MVP Power 6 110 220 VAC High Voltage Input MVP Power 7 Camera Power Standard 12VDC Connector NON STANDARD 24V CONNECTIONS 8 Generic Camera Bracket Installation 9 Wall Mounti...

Page 3: ...ed to any of the following abuse improper use negligence accidents lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlin...

Page 4: ...thin an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of...

Page 5: ...to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camer...

Page 6: ...o conduit feed mouth 4 Push plug into conduit mouth with finger tips till it flush with outside of fitting 5 Repeat steps 1 4 for any other conduit feeds as needed 6 To assure an airtight seal caulk a...

Page 7: ...only 1 10 Power Supply S 250 indoor style in COOLDOME option only 1 Included in S Type Package Not Included in this Package Camera Installation Tools Wall Mounting Bolts Hardware Pole Mount Straps Str...

Page 8: ...6 Socket wrench or box open end wrench or adjustable wrench Wire stripping tool For Wall Mounting Drill and Bits for user supplied fasteners for wall mounting enclosure For Pole Mounting Strapping Ban...

Page 9: ...ll ST MVP is a Chassis similar to shown Locate Green Plug on Chassis Then Unplug from panel mount socket then push aside Connections are made fully inside of ST Then insert similar Plug on 24V Bypass...

Page 10: ...Electrical Working Temp 20 70C MTBF 353 6Khrs min MIL HDBK 217F 25C Power Available to Camera Accessories max MVP using 110 220 VAC input to S Type enclosure Using ONE Output Using BOTH Output Channel...

Page 11: ...osures come standard with a 12VDC Right Angle Barrel Plug 3 3mm x 5 5mm with a 1mm center pin for majority of the IP cameras on the market Camera Power Setup STANDARD 12VDC CONNECTOR Right Angle Stand...

Page 12: ...9...

Page 13: ...e enclosure Always create a drip loop between all external conduit or cable connections between fittings and S Type Housing All cable feeds must be sealed before S Type housing is put into service to...

Page 14: ...lways consult and follow all local and applicable electrical codes to install and service housing Always shut off power before installation and follow all applicable safety practices and guidelines On...

Page 15: ...ide screws removed in first step re assemble Tilt bracket to wall mount as shown Loosen then re tighten screws for Pan Tilt adjustment to arrange housing to desired viewing angle Securely tighten all...

Page 16: ...Safety Ground Front of Power Supply with terminal strip Rear of Power Supply with Input Voltage Selector Select Input Voltage before Hooking up Power Supply 110 VAC or 220 VAC Low Voltage 12 VDC Outp...

Page 17: ...ut Voltage 90 132VAC 176 264VAC Selected by Switch Frequency Range 47 63 HZ Input Current Full Load Typ 4A 115VAC 2A 230VAC Recommended Min Circuit Breaker for 110VAC In 10 A type C Int Electrical Wor...

Page 18: ...15...

Page 19: ...16 S Type Exploded Detail S Type Mounting Detail Strapping Slots wide cl Not to Scale 2 1 3 4 5 6 7 8 9 1 1 1 0 1 2...

Page 20: ...17 S Type Standard Arm Mounting Pattern Holes diameter clearance Not to Scale...

Page 21: ...18 S Type Strong Arm Mount Wall Mounting Pattern Not to Scale...

Reviews: