background image

 

18 

 

 

 

 

 

 

 

 

 

 

 

 

 

    S-Type Strong-Arm Mount 

   Wall Mounting Pattern  

 

       

 

 

 

 

  

 

 

 

 

 

          

 

 

 

 

 

 

Not to Scale 

 

Summary of Contents for COOLDOME S-Type Encolosure series

Page 1: ...Includes MVP COOLDOME models...

Page 2: ...r Installation 5 24V Input MVP Power 6 110 220 VAC High Voltage Input MVP Power 7 Camera Power Standard 12VDC Connector NON STANDARD 24V CONNECTIONS 8 Generic Camera Bracket Installation 9 Wall Mounti...

Page 3: ...ed to any of the following abuse improper use negligence accidents lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlin...

Page 4: ...thin an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of...

Page 5: ...to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camer...

Page 6: ...o conduit feed mouth 4 Push plug into conduit mouth with finger tips till it flush with outside of fitting 5 Repeat steps 1 4 for any other conduit feeds as needed 6 To assure an airtight seal caulk a...

Page 7: ...only 1 10 Power Supply S 250 indoor style in COOLDOME option only 1 Included in S Type Package Not Included in this Package Camera Installation Tools Wall Mounting Bolts Hardware Pole Mount Straps Str...

Page 8: ...6 Socket wrench or box open end wrench or adjustable wrench Wire stripping tool For Wall Mounting Drill and Bits for user supplied fasteners for wall mounting enclosure For Pole Mounting Strapping Ban...

Page 9: ...ll ST MVP is a Chassis similar to shown Locate Green Plug on Chassis Then Unplug from panel mount socket then push aside Connections are made fully inside of ST Then insert similar Plug on 24V Bypass...

Page 10: ...Electrical Working Temp 20 70C MTBF 353 6Khrs min MIL HDBK 217F 25C Power Available to Camera Accessories max MVP using 110 220 VAC input to S Type enclosure Using ONE Output Using BOTH Output Channel...

Page 11: ...osures come standard with a 12VDC Right Angle Barrel Plug 3 3mm x 5 5mm with a 1mm center pin for majority of the IP cameras on the market Camera Power Setup STANDARD 12VDC CONNECTOR Right Angle Stand...

Page 12: ...9...

Page 13: ...e enclosure Always create a drip loop between all external conduit or cable connections between fittings and S Type Housing All cable feeds must be sealed before S Type housing is put into service to...

Page 14: ...lways consult and follow all local and applicable electrical codes to install and service housing Always shut off power before installation and follow all applicable safety practices and guidelines On...

Page 15: ...ide screws removed in first step re assemble Tilt bracket to wall mount as shown Loosen then re tighten screws for Pan Tilt adjustment to arrange housing to desired viewing angle Securely tighten all...

Page 16: ...Safety Ground Front of Power Supply with terminal strip Rear of Power Supply with Input Voltage Selector Select Input Voltage before Hooking up Power Supply 110 VAC or 220 VAC Low Voltage 12 VDC Outp...

Page 17: ...ut Voltage 90 132VAC 176 264VAC Selected by Switch Frequency Range 47 63 HZ Input Current Full Load Typ 4A 115VAC 2A 230VAC Recommended Min Circuit Breaker for 110VAC In 10 A type C Int Electrical Wor...

Page 18: ...15...

Page 19: ...16 S Type Exploded Detail S Type Mounting Detail Strapping Slots wide cl Not to Scale 2 1 3 4 5 6 7 8 9 1 1 1 0 1 2...

Page 20: ...17 S Type Standard Arm Mounting Pattern Holes diameter clearance Not to Scale...

Page 21: ...18 S Type Strong Arm Mount Wall Mounting Pattern Not to Scale...

Reviews: