background image

8

3.

After servicing, reassemble and install in reverse.
Make sure tank O-Ring and sealing areas are free
of any dirt or grit and the o-ring is evenly seated
before replacing cover.

WINTERIZING FILTER

In areas subject to freezing damage, it is mandatory that
the filter, pump and any related components be re-
moved from the pool and stored indoors.  (Refer to
individual components owners guide such as pump,
skimmer, chlorinator, etc., for specific winterizing
instructions.)
1.

Siphon water level down below skimmer opening by
using your vacuum hose and allow water to flow to
an area that can accept a couple of thousand
gallons or more.

2.

Drain tank completely.

3.

Disconnect all line connections.

4.

Remove V-Clamp from filter and remove cover and
gasket.

5.

Remove cartridges, flush out tank, clean cartridges
thoroughly and allow to dry completely.

6.

Reinstall cartridges only after they have dried
completely.  Replace cover and drain cap.

7.

Store all components in a warm dry area indoors.

DAMAGE CAUSED BY FREEZING TEMPERATURES

IS NOT COVERED BY PRODUCT WARRANTY.

LUBE VALVE SHAFT

To lubricate the O-Ring on the valve shaft, depress
valve handle fully and apply lubricant on the shaft
between handle and valve cover.  Then, rotate handle to
distribute lubricant.  Resume normal filter operation by
rotating handle to the Filter position and start pump.

REPAIRS

Servicing should be performed by a qualified dealer.  If
disassembly is attempted, mark each of the parts
assembled position as it relates to its mating parts.  This
assures proper alignment when reassembled.  Malfunc-
tion will occur if not properly assembled.  See your
dealer for original replacement parts.

CAUTION

BEFORE removing filter or pump from pool for servic-
ing, prevent the backflow of water from your skimmer
and return fitting inlet from flowing out of disconnected
hoses.
1.

Remove skimmer cover and basket and plug inside
bottom hole with rag.

2.

Referring to the instructions for your return fitting,
install the Shutoff disc.  Option; stuff a rag into the
return fitting opening.

3.

Disconnect hoses on filter or pump as necessary
when removing for service or repairs.

DRAIN TANK

See Caution Above

1.

Remove tank drain cap to drain.

2.

Remove V-Clamp, cover and large O-Ring from
tank.

Summary of Contents for 0-1802-019

Page 1: ...1775 the original portable pool Shown with Power Pak III not included Generation II Cartridge Filter with 6 Position Valve Model GEN 180 Item No 0 1802 019 Model GEN 240 Item No 0 1802 022 Owner s Gu...

Page 2: ...tion of debris and moisture ACCESSIBILITY The circulation system components should be installed to allow accessibility for inspection repair or replace ment DO NOT alter the pump electrical cord in an...

Page 3: ...ocks provide firm support and keeps standing water and weeds away from electrical parts DO NOT install your filter and pump directly on the ground surface Settling and stressing circulation lines may...

Page 4: ...h to cover return fitting cut out From inside of pool use the board to hold liner against cut out in pool wall Keep hands away from hole to avoid injury From outside of pool use the cut out as guide a...

Page 5: ...disc 66 between o ring 63 and union socket Retighten union nut onto union adaptor firmly INSTALL SUCTION LINE An 8 foot long hose is provided for filter Model GEN 180 and a hard plumb adaptor with cl...

Page 6: ...or twice during this initial stage of filtering the new raw water After this initial filtering stage the cleaning intervals will be extended less frequent allowing longer time periods between cleanin...

Page 7: ...g these vital areas 7 9 CLEAN CARTRIDGES Attach the BLASTER NOZZLE to a garden hose Position cartridge in an upright position supporting with one hand when cleaning Hold the blaster nozzle away from t...

Page 8: ...S IS NOT COVERED BY PRODUCT WARRANTY LUBE VALVE SHAFT To lubricate the O Ring on the valve shaft depress valve handle fully and apply lubricant on the shaft between handle and valve cover Then rotate...

Page 9: ...Y CARD TO TOP PUMP PORT TO POOL RETURN TO FRONT PUMP PORT TO SKIMMER TO WASTE HI FLOW RETURN PAK NOTE CARTRIDGE CONFIGURATION FOR GEN 180 SHOWN See Parts List for GEN 240 part quanities EXPLODED VIEW...

Page 10: ...Cap Gasket Drain Fitting Nut O Ring 1 287 I D Drain Fitting Threaded Adaptor Assembly Manifold Support Manifold Collector Bottom GEN 180 Manifold Collector Bottom GEN 240 Manifold Elbow GEN 180 Manif...

Page 11: ...1 1 1 1 1 2 1 1 1 1 1 Return Fitting Adaptor 36 Band Clamp Hard Plumb Adaptor 28 Band Clamp Return Fitting Return Gasket Union Adaptor O Ring 50mm I D Union Socket Union Nut Winterize Disc Pin Retaine...

Page 12: ...hemically out of filter balance 3 Chemically treat and balance pool water condition 5 Short filter cycles 1 Cartridges clogged with 1 Clean cartridges contaminants or algae 2 Clean cartridges Refer to...