28
12.03
TECHNICAL DATA
The technical data of each dispenser type are given on the rating plate.
Dimensions:
Height:
645 mm
Width:
210 mm
Depth:
455 mm
Weight:
21 kg (net)
Water connection:
Drinking water line with stop valve. Connection to hot water supply
via copper pipes only.
Supply system requirements:
Temperature:
max. 75 °C
Dynamic pressure:
min. 0.8 bar
Static pressure:
max. 10 bar
Water filling capac.: 6.5 l, open boiler
Beverage capacity:
approx. 330 cups/hour with 230 V/3,3 kW (cup size = 100 cc)
or approx. 220 cups/hour with 230 V/2,2 kW
Concentrate capac.: Concentrate packs with 2 l each
Electric connection: Only via power supply plug, otherwise a contact breaking device (min.
3mm) controlling all poles must be installed in the power supply system.
You must earth the dispenser!
In addition, we recommend to install a fault current safety switch.
Length of power
supply cable:
approx. 1.80 m
Acoustic emission:
The A-weighted sound pressure level of the dispenser is below 70 dB.
Further requirements Height:
up to 2,000 m
for installation:
Ambient temperature: 10°C, max. 32°C
Options:
Operating panel with counter and key switch, drip tray assembly, flexible
pressure hose with 3/8" UNF, R3/4" or R3/8" connection,kit "café cool",
heating plate.
Accessories:
Cleaning brush and connecting piece for water inlet
The dispenser is marked with the CE label.
(Low voltage directive, directive for electromagnetic compatibility)
Subject to changes!
Technical Data