30
12.03
3
xxxxx
xxxxx
STOP
ON
OFF
1
2
DESCRIPTION OF THE OPERATING ELEMENTS
Operation
1 LOW TEMPERATURE INDICATOR:
Yellow LED
OFF
: Water temperature in
the boiler and cooling
compartment tempera-
ture are correct
Yellow LED
permanently
ON
: Water temperature in
the boiler is too low.
Cooling compartment
temperature is correct.
2 CONCENTRATE PACK EMPTY
INDICATOR:
Light off
= ready for operation
Shines red
= concentrate pack of this
unit is empty.
Delivery is blocked,
replace the pack.
Flashes
= indicates a malfunction,
call the service.
Yellow LED
flashes (short
flashing
frequency)
: Water temperature in the
boiler is correct.
Cooling compartment
temperature is incorrect.
Yellow LED
flashes (long
flashing
frequency)
: Water temperature in
the boiler is too low.
Cooling compartment
temperature is incorrect.