August 2009
3 - 3
Cafitesse 100 Next Generation
Errors
No. Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Priority
12
Boiler level sen-
sors not detected
Contact bridge in
lever sensor
connector is not
detected
Automatically
when hardware
detects the
contact bridge
Wiring incorrect or sensor con-
nections defective
MCB defective
1.
2.
Check wiring or replace sensor
connections (see chapter 5K)
Replace MCB (see chapter 5K)
1.
2.
120
17
Leaking outlet
valves (small
leak)
The refill cycles
have occurred
5 times without
dispensing
Lock/clear
button
1)
Leaking outlet valves
Check the outlet valves
Check on other leakages
1.
2.
18
Leaking outlet
valve (severe
leak)
More than 5
refill cycles have
occurred without
dispensing
Lock/clear
button
1)
After the
reset
condition
the timer
restarts
Leaking outlet valves
Check the outlet valves
Check on other leakages
1.
2.
101
19
Refilling boiler
takes too long
(17)
Inlet valve was
open for 2
minutes
Lock/clear
button
1)
On reset
the refilling
starts
again
Water supply tap not open or
blocked
Water filter clogged or defec
-
tive
Water pressure too low
Inlet valve defective
Hoses clogged or
defective
1.
2.
3.
4.
5.
Open or clean tap
Clean or replace water filter
Check water pressure (see
chapter 2)
Replace inlet valve
Clean or replace hoses
1.
2.
3.
4.
5.
100
21
Boiler water hea-
ting is defective
Heating was con-
tinuously on
for 45 minutes
Lock/clear
button
1)
May occur
after ERR
10 and
ERR 11
Wiring incorrect or connections
defective
Temperature sensor defective
MCB defective
Heating elements or relays
defective
1.
2.
3.
4.
Check wiring or replace con-
nections (see chapter 5K)
Replace temperature sensor
(see chapter 5A)
Replace MCB (see chapter 5K)
Replace heating elements or
relays (see chapter 5A)
1.
2.
3.
4.
115
1)
Errors are reset by pressing the Lock/clear button in cleaner-, operator-, service- or development mode is shown
2)
Not valid for Cafitesse 100 NG
3)
Valid for Cafitesse 120 NG only
Summary of Contents for Cafitesse 110
Page 2: ... 2009 Douwe Egberts Coffee Systems International DRAFT Version August 2009 D R A F T ...
Page 22: ...D R A F T Cafitesse 100 Next Generation Installation Putting into operation 2 20 August 2009 ...
Page 54: ...Cafitesse 100 Next Generation Programming 4 20 August 2009 ...
Page 58: ...D R A F T Cafitesse 100 Next Generation Functions Overview of assemblies 5 August 2009 ...
Page 71: ...Cafitesse 100 Next Generation Functions water system August 2009 5A 13 ...
Page 82: ...Cafitesse 100 Next Generation Functions dosing system 5C 10 August 2009 ...
Page 93: ......