August 2009
3 -
Cafitesse 100 Next Generation
Errors
No. Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Priority
81
UI error
No response or
error reported
Reset on reco-
very
Wiring incorrect or defective
UIB defective
MCB defective
1.
2.
3.
Check and correct wiring
Replace UIB
Replace MCB
1.
2.
3.
82
Payment module
error
No response or
error reported
Lock/clear
button
1)
Payment system enabled, but
not connected.
Wiring incorrect or defective
Coin/card/waiter system not
connected or defective
Power issue in payment sy-
stem
Control board payment system
defective
MCB defective
1.
2.
3.
4.
5.
6.
Check and correct payment
settings
Correct or replace wiring
Check and connect/replace
coin/card/waiter system
Check power unit in payment
system and wiring
Replace control board payment
system
Replace MCB
1.
2.
3.
4.
5.
6.
83
Flavor module
error
No response or
error reported
Lock/clear but-
ton
1)
not active
not active
84
Foamino module
error
No response or
error reported
Lock/clear but-
ton
1)
not active
not active
85
Cold module
error
No response or
error reported
Lock/clear but-
ton
1)
not active
not active
90
Check sum error
parameter
.field 1
Software
Lock/clear
button
1)
, after
initialization has
indicated that the
checksum is OK
The memory test of the MCB
detected a memory
failure.
Replace the MCB.
210
91
Check sum error
parameter
.field 2
Software
Lock/clear
button
1)
, after
initialization has
indicated that the
checksum is OK
The memory test of the MCB
detected a memory
failure.
Replace the MCB.
210
3.5 Errors hardware and network
1)
Errors are reset by pressing the Lock/clear button in cleaner-, operator-, service- or development mode is shown
2)
Not valid for Cafitesse 100 NG
3)
Valid for Cafitesse 120 NG only
Summary of Contents for Cafitesse 110
Page 2: ... 2009 Douwe Egberts Coffee Systems International DRAFT Version August 2009 D R A F T ...
Page 22: ...D R A F T Cafitesse 100 Next Generation Installation Putting into operation 2 20 August 2009 ...
Page 54: ...Cafitesse 100 Next Generation Programming 4 20 August 2009 ...
Page 58: ...D R A F T Cafitesse 100 Next Generation Functions Overview of assemblies 5 August 2009 ...
Page 71: ...Cafitesse 100 Next Generation Functions water system August 2009 5A 13 ...
Page 82: ...Cafitesse 100 Next Generation Functions dosing system 5C 10 August 2009 ...
Page 93: ......