TECHNICAL REFERENCE
ENGINEERED FOR STORES WITH AMBIENT
CONDITIONS NOT TO EXCEED 75° AND 55%
RELATIVE HUMIDITY. DUE TO ENGINEERING
IMPROVEMENTS SPECIFICATIONS MAY CHANGE
WITHOUT NOTICE. ALL MEASUREMENTS ARE
TAKEN PER ASHRAE-72-2005 SPECIFICATIONS.
NUMBERS ARE BASED ON STANDARD CASE SIZES.
CONSULT ENGINEERING.
DI-H-MD-2
Self-Service Open Multi-Deck Hot Octagonal Island Merchandiser
505 & 606 (Deli)
DI-H-MD-2
NOTES:
• "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time.
SELF-SERVICE DATA
Case
Length
Top
Heaters
Bottom
Heaters
Lights
Shelves
(per shelf)
Total Amps
(208-3-60)
(per shelf)
Qnty
Watts
(Each)
Qnty
Watts
(Each)
Qnty
Watts
(Each)
Qnty
Watts
(Each)
L1
L2
L3
505
8
250
8
345
4
40
8
92
19.88 21.10 20.45
606
8
250
8
620
4
40
8
92
26.50 28.60 27.49
ELECTRICAL DATA
Case
Length
Fans
Per
Case
Control Fans
208 Volts
Amps
Watts
505
1
0.11
22
606
1
0.11
22
LIGHTING DATA
Case
Length
Lights
Per
Row
Light
Length
Incandescent
Lighting
(Per Light Row)
Amps
Watts
505
4
---
0.33
40
606
4
---
0.33
40
NOTES:
• "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time.
Rev. Date
Rev. #
Rev. Title
07-30-21
1
NEW STANDARDS
9