A1 OPERATING DATA
ORZ
Doors
Anthony
Gemtron
ELMD
Eliminaator
5
Eliminaator 2
5
Polar RE
Polar LE
Polar EF
120 Volts
120 Volts
120 Volts
120 Volts
120 Volts
120 Volts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
2-door
2.1
256
1.7
209
1.2
145
2.1
254
1.4
166
1.2
140
3-door
3.2
378
2.6
309
1.8
213
3.2
378
2.1
246
1.7
207
4-door
4.2
502
3.4
403
2.3
276
4.2
501
2.7
325
2.3
273
5-door
5.2
625
4.2
506
2.9
346
5.3
632
3.4
412
2.9
347
6-door
6.2
743
5.1
607
3.5
416
6.2
747
4.0
483
3.4
405
Electrical Data
Defrosts
7
Per Day
Run-Off
Time (min)
Electric Defrost
Timed-Off Defrost
Hot Gas Defrost
Fail-Safe
(min)
Termination
Temp (°F)
Fail-Safe
(min)
Termination
Temp (°F)
Fail-Safe
(min)
Termination
Temp (°F)
1
13 - 15
46
60
- - -
8
- - -
24
73
1 Tank heater and fan motors share the same circuit (seperate cycles). Be certain that the circuit wiring is properly sized to handle the higher current draw of the tank heater.
2 3-phase load is unbalanced.
3 Figure given is maximum line amperage per phase.
4 Low-power lights. High-power option available.
5 Values provided are for doors with no heat on the glass.
6 Average discharge air velocity at peak of defrost.
7 If a discharge air temperature sensor is used to terminate defrost cycle, termination temperature should be set to 55ºF.
8 NOTE: “- - -” indicates that the feature is not an option with this case model.
Guidelines & Control Settings
Defrost Controls
Anti-Condensate Heater Data
Application
Door
BTUH/door
Evaporator
(°F)
Superheat
Set Point @ Bulb
(°F)
Discharge
Air
(°F)
Discharge
6
Air
Velocity
(FPM)
Conventional Parallel
Frozen
ELMD/Polar RE
1044
1014
-7
3 - 5
-3
400
Eliminaator/2; Polar LE/EF (multi-door)
988
960
-7
3 - 5
-3
400
Ice Cream
ELMD/Polar RE
1091
1060
-15
3 - 5
-10
400
Eliminaator/2; Polar LE/EF (multi-door)
1027
998
-15
3 - 5
-10
400
Doors
Fans
Per Case
High Efficiency
Fans
Tank
1
Heater
Defrost Heaters
(1-Phase)
Defrost Heaters
2
(3-Phase)
120 Volts
120 Volts
208 Volts
240 Volts
208 Volts
240 Volts
Amps
Watts Amps Watts Amps
Watts
Amps
Watts
Amps
3
Watts Amps
3
Watts
2-door
2
0.6
50
1.3
152
7.5
1552
8.6
2068
6.5
1552
7.5
2068
3-door
3
1.0
75
1.5
171
10.9
2274
12.6
3018
9.5
2274
10.9
3018
4-door
4
1.3
100
1.9
226
14.3
2984
16.6
3992
12.4
2984
14.4
3992
5-door
5
1.6
125
2.3
275
17.5
3640
20.2
4840
15.1
3640
17.4
4840
6-door
6
1.9
150
2.7
320
20.3
4224
23.4
5624
17.6
4224
20.3
5624
Lighting Data
Doors
LED Lighting
Optimax
Pro
4
GE
IMMERSION
Crossfire
4
/Polaris
120 Volts
120 Volts
120 Volts
Amps Watts Amps Watts Amps Watts
2-door
0.3
39
0.3
32
0.3
30
3-door
0.5
58
0.4
48
0.4
45
4-door
0.6
77
0.5
64
0.5
60
5-door
0.8
96
0.7
80
0.6
75
6-door
1.0
115
0.8
96
0.8
90
Summary of Contents for Hillphoenix ONRZ
Page 23: ...ELECTRIC DEFROST 1 PHASE E2 ELECTRICAL WIRING ...
Page 24: ...E3 ELECTRIC DEFROST 3 PHASE ELECTRICAL WIRING ...
Page 25: ...E4 ELECTRIC DEFROST HOT GAS ELECTRICAL WIRING ...
Page 31: ...J2 SEISMIC BRACKETS 5 BRACKETS ...
Page 32: ...J3 SEISMIC BRACKETS 7 BRACKETS ...
Page 33: ...J4 SEISMIC BRACKETS 11 BRACKETS ...