10
3.OO maintenance
(continued)
3.O2 Routine Maintenance Instructions
Step 1.
Unscrew and remove
lower end from assembly.
Step 2.
Pull down on shaft, rotate shaft
90° and remove.
Step 3.
Remove shaft with gasket and
install new. If damage on sealing
surface of shaft, replace shaft.
Step 6.
Place new motor piston
carefully into pump body and
replace lid.
Step 5.
Remove motor piston from
pump body.
Step 7.
Place shaft into the motor piston.
Step 9.
Replace lower end assembly and lid
onto the pump body. Ensure o-ring is
still in the lid before putting it back on.
Step 4.
Hold body firmly and unscrew
the lid. If lid is tight, use 1' (25
mm) socket to loosen.
Step 8.
Rotate shaft 90° to lock into place.
Gently pull down to ensure shaft
is locked.
↓
↓
Summary of Contents for HYDRO AquaBlend Xtreme