4.OO troubleshooting
4.O1 New Install Troubleshooting
Problem
Cause
Solution
1. No Clicking Sound
a. Fluid not flowing through unit
•
Are the red plugs at the inlet, outlet and suction tube fitting
openings removed?
•
Is the unit installed backward? The arrow on the unit must
point in the direction of the fluid flow.
•
If still not clicking, do not open the upper body. Call Hydro
Systems customer service.
b. Fluid flowing through unit
•
Fluid rate is below or exceeds rated service flow of injector.
(See Specifications for maximum flow rate page 5). Maximum
number clicks = 28 per 15 seconds.
•
Ensure all air is out of the unit by pressing the bleeder button
in, on the lid, until water comes out.
•
If below increase flow rate, if above, reduce flow rate.
•
Operating pressure exceeds maximum limit. Install a pressure
reducer valve.
(See Specifications for maximum flow rate page 5).
4.O2 Injector in Operation or After Scheduled Maintenance Troubleshooting
Problem
Cause
Solution
1. No Clicking Sound
a. Air trapped in unit
b. By-pass valve not open
c. Broken springs
d. Dirty or plugged inlet filter
e. Main piston assembly worn
f. Main body worn or scored
•
Release trapped air by pressing the bleeder button in until
water comes out.
•
Set valve to the closed position.
•
Replace Motor Piston assembly, Clean fluid filter.
•
Ensure mesh size is correct for proper filtration. Clean filter.
•
Replace Motor Piston assembly. Clean fluid filter.
•
Replace body and piston.
2. Clicking sound. No suction of solution
a.
Cracked or loose suction hose
b.
Dosage gasket worn or
installed incorrectly
c.
Suction tube or suction tube fitting
cracked, leaking or clogged suction
tube filter
d. Check valve #11 leaking
•
Check for proper fit and/or replace.
•
Replace. Ensure during maintenance replacement that dosage
gasket was installed correctly.
•
Replace and/or clean as necessary.
•
Clean and/or replace as necessary.
3.
Clicking Sound.
Under Injecting or Unit Operates
at High-flow and not at Low Flow.
a.
Dosage gasket worn
b. Inner cylinder worn
c. Broken springs
d.
Main piston assembly worn
e. Main body worn or scored
•
Replace.
•
Replace inner cylinder and gasket.
•
Replace Motor Piston assembly, Clean fluid filter.
•
Replace Motor Piston assembly. Clean fluid filter.
•
Replace Body & Piston.
4.
Fluid Re-filling Solution Tank
a.
Check valve leaking or dirty
b.
Washer seal on check valve is
swollen or chemical attack
•
Check seat area on suction tube fitting. Check valve and seal
must fit loose in the suction tube fitting. Clean seal and inside
fitting for debris.
•
Replace with new check valve assembly.