background image

15

6.O1 Limited Warranty

 

Seller

 warrants solely to 

Buyer

 the Products will be free from defects in material and workmanship under normal use and 

service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; 
(b) and products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, 
abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event 
the Products are altered or repaired by 

Buyer

 without 

Seller’s

 prior written approval, all warranties will be void.

No other warranty, oral, express or implied, including any warranty of merchantability or fitness for any particular 
purpose, is made for these products, and all other warranties are hereby expressly excluded.

Seller’s

 sole obligation under this warranty will be, at 

Seller’s

 option, to repair or replace F.O.B.

 Seller’s

 facility in Cincinnati, 

Ohio any Products found to be other than as warranted.

6.O2 Limitation of Liability

Seller’s

 warranty obligations and 

Buyer’s

 remedies are solely and exclusively as stated herein. 

Seller 

shall have no other 

liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims 
for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or 
breach of warranty.

6.OO warranty 

Hydro Systems

3798 Round Bottom Road
Cincinnati, OH 45244

Phone  

513.271.88OO

Toll Free

 

 

8OO.543.7184 

Fax

  

513.271.O16O

Web

  

hydrosystemsco.com

HYD10099002  Rev A 9/18

Congratulations on Your Purchase!

We make the best and most reliable fluid-driven injectors available. 
Hydro Systems will provide for replacement of all parts proven to 
be defective in material or workmanship from the date of purchase 

for the following periods:  

1

 Year

Covers your unit from manufacturing 
and material 
defects only.

Hydro Systems products are warranted to be free from defects 
in materials and workmanship for the above time frames. Hydro 
Systems will at its sole option repair or replace any component 
that fails in normal use. Any repairs made under warranty shall not 
extend the initial warranty period.

To Maintain Your Warranty

Your only responsibility is ordinary maintenance - filtering incoming 
fluid, replacing the O-ring and dosage piston/gasket when worn. 
Seals and O-rings are not covered under the warranty. 

To Return an injector for Warranty or Non-Warranty repair:

Contact Hydro Systems Company or your local distributor for return information.

This warranty is not valid if the defects are found to be due to the 
product’s misuse, lack of maintenance, fluid impurities such as 
sand or iron, defective installation, freezing,  fluid hammer, abuse, 
unwanted side effects due to the chemicals you choose to inject 
or service provided by anyone who is not an authorized service 
provider. Hydro Systems declines any responsibility if the product 
is not used in compliance with the operating instructions and 
specifications as indicated in this owner’s manual. 

IN NO EVENT SHALL HYDRO SYSTEMS BE LIABLE FOR ANY 
INCIDENTAL, SPECIAL; INDIRECT, OR CONSEQUENTIAL DAMAGES, 
WHETHER RESULTING FROM THE USE, MISUSE OR INABILITY TO 
USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT.

There is no warranty expressed or implied relating in any way to 
products used in conjunction with Hydro Systems.

Hydro Systems or authorized distributor shall not be liable for 
incidental or consequential damage, such as any economic loss. 
Hydro Systems retains the exclusive right to repair or replace the 
product. Such remedy shall be your sole and exclusive remedy for any 
breach of warranty. There are no warranties, expressed or implied, 
which extend beyond those described above.

6.O2 Contact

Summary of Contents for HYDRO AquaBlend Xtreme

Page 1: ...user manual AquaBlend Xtreme ...

Page 2: ......

Page 3: ...ration 8 3 OO maintenance 3 01 General Maintenance Tips Schedule 9 3 02 Routine Maintenance Instructions 10 4 OO troubleshooting 4 01 New Install Troubleshooting Table 11 4 02 Injector in Operation or After Scheduled Maintenance Troubleshooting Table 11 5 OO injector repair parts 5 01 Body and Piston 12 5 02 Lower End Parts 0 2 2 13 5 03 Lower End Parts 0 78 5 14 6 OO warranty and contact 6 01 Lim...

Page 4: ...aintaining your equipment reassemble equipment according to instruction procedures Be sure all components are firmly screwed or latched into position equipment clean to maintain proper operation only to water tap outlets 5 PSI Minimum 90 PSI Maximum and Maximum water temperature 100 F if the unit is used to fill a sink or the discharge hose can be placed into a sink The unit must be mounted so tha...

Page 5: ... 500 1 50 Model 0 78 5 1 128 1 20 Pipe Coupling 3 4 npt ght bsp Housing PVDF Dosing Accuracy 10 of ratio Repeatability 5 Pressure Loss Available on request Maximum Temperature 100 F 38 C Minimum Temperature 34 F 1 C Maximum vertical suction of concentrate 13 Feet 396 Centimeters Maximum horizontal suction of concentrate 49 Feet 1493 Centimeters Self Priming Yes Seal Material Available Engineered F...

Page 6: ...irt debris and other contaminants in the solution container may cause excessive wear to the unit Fluid Temperature Min 34 F 1 C Max 100 F 38 C Maximum Fluid Pressure 90 psi 6 2 bar Install a pressure regulator and or pressure relief valve to ensure operating pressure does not exceed the maximum specification Before Removing An Injector From The System Release fluid pressure While the system is in ...

Page 7: ...e solution container on a level below the injector suction tube fitting Using the inlet side as a shut off valve could cause full strength solution to siphon into the feed line Solution Container Use any size container A lid or cover is recommended To connect your solution container gently push the end of the suction tube onto the bottom of the suction tube fitting assembly Place the filter into t...

Page 8: ... 5 for your model Change Feed Injection Rate The feed rate on the injector is adjustable EVEN WHILE OPERATING AND UNDER PRESSURE To change feed rate see Fig 1 and Fig 2 1 Lift lock ring Fig 1 2 Rotate Ratio Adjuster Sleeve Fig 2 up or down to the desired setting Use arrows at top of the Ratio Adjuster Sleeve to line up with the desired feed rate on the sleeve 3 Return ring to lock position by push...

Page 9: ...g in fresh water Replace if necessary Keep filter screen off bottom of solution container to prevent dirt and precipitate from clogging filter Clean Inlet Filter Clean or replace inlet filter as required to increase the life of the unit as well as reduce pressure loss Bypass Injector When not in use place the injector in bypass mode by using the three valve bypass Storage For extended storage rins...

Page 10: ...place shaft Step 6 Place new motor piston carefully into pump body and replace lid Step 5 Remove motor piston from pump body Step 7 Place shaft into the motor piston Step 9 Replace lower end assembly and lid onto the pump body Ensure o ring is still in the lid before putting it back on Step 4 Hold body firmly and unscrew the lid If lid is tight use 1 25 mm socket to loosen Step 8 Rotate shaft 90 t...

Page 11: ...ing the bleeder button in until water comes out Set valve to the closed position Replace Motor Piston assembly Clean fluid filter Ensure mesh size is correct for proper filtration Clean filter Replace Motor Piston assembly Clean fluid filter Replace body and piston 2 Clicking sound No suction of solution a Cracked or loose suction hose b Dosage gasket worn or installed incorrectly c Suction tube o...

Page 12: ...unting bracket kit 2 HYD017200XT Kit H Motor piston replacement 3 HYD102601NPT HYD102601BSP Body NPT PVDF AquaBlend Xtreme Body BSP PVDF AquaBlend Xtreme 1 2 3 5 O1 Body and Piston Exploded Parts Diagram Service Parts List 5 OO injector repair parts ...

Page 13: ...017211XT Kit B Wear kit 3 HYD017213XT Kit D Check valve kit 4 HYD017214XT Kit E Wear parts maintenance kit 5 HYD017216XT Kit G Complete lower end kit 1 2 3 5 O2 lower end parts O 2 2 exploded parts diagram Service Parts List 5 OO injector repair parts continued 1 2 3 4 5 ...

Page 14: ...escription 1 HYD017220XT Kit A Dosage gasket kit 2 HYD017221XT Kit B Wear kit 3 HYD017223XT Kit D Check valve kit 4 HYD017224XT Kit E Wear parts maintenance kit 5 HYD17226XT Kit G Complete lower end kit Service Parts List 5 OO injector repair parts continued 1 2 3 4 5 ...

Page 15: ...fective in material or workmanship from the date of purchase for the following periods 1 Year Covers your unit from manufacturing and material defects only Hydro Systems products are warranted to be free from defects in materials and workmanship for the above time frames Hydro Systems will at its sole option repair or replace any component that fails in normal use Any repairs made under warranty s...