background image

Package Should Contain:
1.  Satellite dispenser
2.  Product inlet tubing, 1/4" x 12"
3.  Ceramic weight.
4.  Footvalve
5.  Metering tip kit
6.  Instruction sheet.

3.  Insert product inlet assembly into bottle and secure dispensing unit to bottle. Use velcro strap to further secure bottle    
handle to dispensing unit.
4.  Connect water supply hose of at least 3/8" ID to water inlet swivel.
(Minimum 25 PSI pressure, with water running, is  required for proper operation.)

10092190

10/09 

Hydro Systems 3798 Round Bottom Road, Cincinnati, OH 45244   Phone: (513) 271-8800  Fax: (513) 271-0160

protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals, fi lling or 
emptying equipment, or changing metering tips.

observe safety and handling instructions of the chemical manufacturer.

direct discharge away from you or other persons or into approved containers.

dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise CAUTION when maintaining your equipment.

reassemble equipment according to instruction procedures. Be sure all components are fi rmly screwed or latched into position.

equipment clean to maintain proper operation.

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

WEAR

ALWAYS

KEEP

 

Please use this equipment carefully and observe all warnings andcautions.

                             ***************************************************NOTE ********************************************

Problem Cause 

Solution

1.  No discharge 

a.  No water 

a.  Open water supply

   

b.  Valve not open 

b.  Trigger not fully depressed

   

c.  Eductor clogged 

c.  Look for obstruction, remove if possible

   

d.  Foamer/Sprayer pivot not 

d.  Rotate to stops, top or bottom

  

 in 

proper 

location

2.  No concentrate draw 

a.  Clogged  foot strainer 

a.  Clean or replace

   

b.  Metering tip or eductor has scale 

b.  Clean (descale)* or replace

  

 build-up

   

c.  Low water pressure 

c.  Minimum 25 PSI (with water running)

   

   

  required to operate unit properly

   

d.  Switch in "OFF" position 

d.  Switch to "ON" position 

   

e.  Air leak in chemical pick-up tube 

e.  Put clamp on tube or replace tube if brittle

   

f.  Clear plastic tip installed in inlet 

f.  Replace with colored metering tip 

  

 pick-up 

stem

3.  Excess concentrate draw  a.  Metering tip not in place 

a.  Press correct tip 

fi

 rmly into barb on pick-up stem

4.  Failure of unit to turn off 

a.  Trigger lock is on 

a.  Release trigger lock

TROUBLESHOOTING CHART:

FOAMER/SPRAYER
MODEL 5823 & 5824

C

ONTINUED

 

ON

 

NEXT

 

PAGE

....

2.   Select metering tip using guide on 
next page. Install metering tip into barb 
in center of cap. Cut product inlet tube to 
desired lentgh for selected bottle, slide 
weight over end of tube, insert footvalve 
into end of tube. NOTE: REMEMBER 
TO CHECK FOOT VALVE STRAINERS 
PERIODICALLY FOR CLOGGING: 
CLEAN IF NECESSARY.

5.  Install Foam or Spray Nozzle 
to front of dispenser. Move product  
switch to "ON" to dispense product. 
Switch to "OFF" to rinse. Rotate 
front nozzle for jet rinse.

Installation and Operation:

1.  Remove dispensing unit from box.

6.  To remove Foam or Spray 

 

Nozzle. Lift up on front. Snap other 
Nozzle in place when not in use.

LIFT

ON

Reviews: