Metering Tip Selection:

The fi nal concentration of the dispensed solution is related to 
both the size of the metering tip opening and the viscosity of 
the liquid being siphoned. For water-thin products, the chart 
at right can be used as a guideline. If product is noticeably 
thicker than water, consult the Measurement of Concentration 
Procedure below to achieve your desired water-to-product 
ratio. Because dilution can vary with water temperature and 
pressure, actual dilution achieved can only be ascertained 
by using the Measurement of Concentration Procedure. The 
clear, undrilled tip is provided to permit drilling to size not 
listed should you need a dilution ratio that falls between 
standard tip sizes.

NOTE:  Refer to parts diagram if unfamiliar with names of 
system components.

Measurement of Concentration:

You can determine the dispensed water-to-product ratio for 
any metering tip size and product viscosity. All that is required 
is to operate the primed dispenser for a minute or so and note 
two things: the amount of dispensed solution, and the amount 
of concentrate used in preparation of the solution dispensed. 
The water-to-product ratio is then calculated as follows:

 

 

Dilution Ratio (X:1) where X = Amount of 

Mixed Solution — Amount of Concentrate Drawn
 

  

 

 

 

 

 

Amount of Concentrate Drawn 

Dilution Ratio, then, equals X parts water to one part concen-
trate (X:1). If  the test does not yield the desired ratio, choose a 
diff erent tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your concentrate supplier 
for further information on these alternative methods and the materials required to perform them.

Parts Diagram List:

1   238100 

Strainer 

washer

2    10092189 

Kit, cap replacement

3    690014 

Metering tip kit 

4    10027303 

Pick-up tube, 12" 

5   509900 

Ceramic 

weight

6   10089410  Footvalve, 

Viton

 

   

* EPDM also available order 10076302

Description

Part No.

Key

5

4

6

3

1

2

7.  Depress trigger to begin dispensing desired concentrate solution; release trigger to stop fl ow of solution. To lock trigger 
in 

"ON" 

position depress and hold trigger while sliding red lock button back then release trigger. To release lock push red 

lock button up and slightly forward to stop fl ow of solution.

7.  To disconnect, turn off water source.  Make sure on/off valve is in OFF position.  Disconnect water supply hose from unit. 

TRIGGER

LOCK BUTTON

8. Bottle 

Conversion.

Your dispenser was delivered to fi t an "F-Style" or 
"Round Gallon" bottle. The cap can be converted from 
one style to the other by removing the screw to the 
cover, and relocating the cap. Replace the button insert 
into the open hole. Then reinstall the cover and screw.

APPROXIMATE DILUTIONS

AT 40 PSI FOR WATER-THIN PRODUCTS (1.0 CP)

Tip

Color

Orifi ce

Size

Std. Drill

Number

Ratio

(per Eductor Flow)

2.5 GPM

Foamer

Sprayer

No Tip

.187

(3/16)

 7:1

13:1

Grey

.128

(30)

7.5:1

13:1

Black

.098

(40)

 8:1

13:1

Beige

.070

(50)

 8:1

15:1

Red

.052

(55)

 11:1

17:1

White

.043

(57)

 15:1

22:1

Blue

.040

(60)

 18:1

24:1

Tan

.035

(65)

 22:1

32:1

Green

.028

(70)

 32:1

46:1

Orange

.025

(72)

 45:1

57:1

Brown

.023

(74)

 49:1

64:1

Yellow

.020

(76)

73:1

76:1

Aqua

.018

(77)

82:1

87:1

Purple

.014

(79)

140:1

140:1

Pink

.010

(87)

280:1

280:1

Reviews: