background image

 

 

 

 

NEP-ZL101151 

07.2019 

 
 
 
 
 

 
 

 

 

OPERATING INSTRUCTIONS 

AND PARTS LIST

 

SERIES HGS 

BUNG MOUNT, GEAR 

DRIVE DRUM MIXER: 430 

RPM 

 

DESCRIPTION 

The Neptune Series HGS high-viscosity gear drive mixer is designed to 
mount  on  the  standard  2”  bung  of  a  55  gallon  closed  steel  drum.  The 
rugged  430  rpm  gearbox  provides  plenty  of  torque  to  permit  mixing  of 
high  viscosity  or  shear  sensitive  fluids.  The  30”  long  316SS  shaft 
includes six fixed paddles and a folding propeller that fits through the 2” 
bung and opens to 3.75“ when the mixer is operating. 

 

OPERATING SPECIFICATIONS: 

 

MODEL 

MOTOR HP 

MAX VISCOSITY 

HGS-2.0 

1/3 HP 

4000 CPS 

HGS-3.0 

1/2 HP 

16,000 CPS 

HGS-5.0 

3/4 HP 

24,000 CPS 

HGS-6.0 

1 HP 

32,000 CPS 

HGS-4.0 

1/4-1/2 HP AIR MOTOR 

24,000 CPS 

HGS-7.0 

3/4-1 HP AIR MOTOR 

32,000 CPS 

 

ASSEMBLY INSTRUCTIONS 

This mixer requires only minimal assembly. The gear 
reducer is factory-filled with SAE 40 weight oil however 
you should check oil level prior to operating mixer. 

 

1. Insert the end of the shaft with a flat into the 
coupling and tighten the set screws. 

 

2. Attach the propeller to the end of shaft. 

 

3. The motor must be installed, wired and properly 
fused by qualified personnel in accordance with the 
latest local and national electrical codes. 

 

 

OPERATING INSTRUCTIONS 

 

1. Make certain that all hardware on the mixer is  
    completely tightened before operating the mixer. 

 

2. Screw the adapter securely into the 2” NPT bung  
    prior to operating the mixer. 

 

3. Note that folding propeller blades will lift up and  
    open to 3.75” when the mixer is operating. 

 

4. A filter/regulator should be used with air motors. 

 

SAFETY INSTRUCTIONS 

Always follow these operating instructions fully. Failure to do  
so could result in serious bodily injury! 

 

1. Do not touch moving parts or attempt to make  

   

adjustments while the mixer is operating! 

 

2. Make certain the mixer is properly grounded! 

 

3. Always wear appropriate safety equipment including 
    face protection when removing the mixer or moving it to  
    another drum! 

 

4. Air motors are designed to be driven by compressed  
    air only and under no circumstances be driven with any  
    other gases! 

 

5. Always disconnect and lockout electric power or air  
    supply before servicing mixer! 

 

MAINTENANCE INSTRUCTIONS 

 

Periodically check and tighten the set screws as necessary. 

 

Also refer to Mixer Safety Supplement NPT-10001-E-01

 

 

 

Reviews: