2 7
D
ETERMINE
IF
U
NIT
NEEDS
A
P
LINTH
Triton Systems offers two (2) metal-constructed optional plinths w/leveling
feet. A “plinth” is a platform on which the ATM rests or is secured. A plinth
enables the ATM to be installed at the required height through the wall. The
plinths come in 2 heights: 2-3/8” (61mm - shown below) and 4-3/4” (122 mm).
You can raise the unit by a fixed amount (2-3/8"or 4-3/4") and still be able to
adjust up using the plinths leveling feet. To determine if you need to order a
plinth with your unit, a few measurements will be needed at the site.
For sites that currently have a wall opening:
1.
Measure from the bottom of opening to inside floor (Figure 1).
2.
Cabinet dimensions are 26-1/2" from bottom of sleeve to base of cabinet
(Figure 2).
3.
Subtract the difference to determine if a plinth is needed or what size plinth
to order or build. If difference is less than 2-3/8"(for example), you may
construct your own to fit.
(Caution: The leveling feet on the cabinet itself
should not be used to raise the unit significantly)
Figure 1. Determine height of
opening to inside floor.
Leveling feet
Wall tab
Cabinet mounting holes
Floor anchor holes
Cabinet mounting holes
Figure 2. Height of cabinet base to
bottom of sleeve (28").
26- 1/2"
S
ITE
P
REPARATION
/I
NSTALLATION
Summary of Contents for Triton FT5000
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK 8 FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Page 9: ...9 ATM INSTALLATION FOR ACCESSIBILITY ...
Page 21: ...21 ATM ENVIRONMENTAL PRECAUTIONS CHECKLIST ...
Page 23: ...23 SITE PREPARATION INSTALLATION Ground exterior ...
Page 44: ...44 FT5000 SITE PREPARATION AND INSTALLATION GUIDE THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 45: ...45 POWER AND COMMUNICATION ...
Page 48: ...48 THIS PAGE INTENTIONALLY LEFT BLANK FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Page 49: ...49 NMD 100 DISPENSING MECHANISM REMOVAL INSTALLATION ...
Page 54: ...54 THIS PAGE INTENTIONALLY LEFT BLANK FT5000 SITE PREPARATION AND INSTALLATION GUIDE ...
Page 55: ...55 REAR SERVICE PANEL RSP TCP IP and VSAT INSTALLATION CONNECTIVITY ...